Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis

Abstract: Introduction: Pulse pressure variation (PPV) has been shown to be useful to predict fluid responsiveness in patients ventilated at tidal volume (Vt) >8 mL kg−1. Nevertheless, most conditions in critical care force to use lower Vt. Thus, we sought to evaluate the operative performance of PPV when a Vt ⩽8 mL kg−1 is used during mechanical ventilation support. Methods: We searched PubMed and Embase databases for articles evaluating the operative performance of PPV as a predictor of fluid responsiveness in crit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0
4

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(24 citation statements)
references
References 44 publications
0
14
0
4
Order By: Relevance
“… 6 The performance of PPV was evaluated in a systematic review and meta-analysis of 19 studies (777 patients) ventilated with tidal volumes <8 mL/kg. 16 In 935 fluid challenges, 51.1% patients were found to be fluid responsive. PPV of 10% had the fitted sensitivity of 0.65 (95% CI: 0.57–0.73) to predict FR, and the specificity was 0.79 (95% CI: 0.73–0.84).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“… 6 The performance of PPV was evaluated in a systematic review and meta-analysis of 19 studies (777 patients) ventilated with tidal volumes <8 mL/kg. 16 In 935 fluid challenges, 51.1% patients were found to be fluid responsive. PPV of 10% had the fitted sensitivity of 0.65 (95% CI: 0.57–0.73) to predict FR, and the specificity was 0.79 (95% CI: 0.73–0.84).…”
Section: Discussionmentioning
confidence: 99%
“…This is similar to our findings for PPV, with sensitivity of 77% and a specificity of 72% but with lower AUROC. 16 The dynamic indices rely on change in intrathoracic pressure. In patients with low lung compliance due to ARDS, the changes in intrathoracic pressure induced by low TV are too small to affect the stroke volume, leading to inability of PPV or SVV to predict fluid responsiveness.…”
Section: Discussionmentioning
confidence: 99%
“…Preload dependency was assessed by SVV and patients were ventilated with a tidal volume (TV) of 7 ml kg −1 ideal body weight, which is associated with lower levels of postoperative complications 29 . Low levels of TV have previously demonstrated to be feasible when using SVV for assessment of preload dependency 30,31 …”
Section: Discussionmentioning
confidence: 99%
“…According to a meta-analysis, PPV was superior to predict responsiveness than other dynamic preload indexes in human patients under mechanical ventilation with tidal volumes ranging from 8 to 12 ml/kg ( 31 ). Although, PPV values >12.5% accurately discriminate responders from non-responders to a fluid challenge ( 31 ), this index has limited clinical application in the ICU setting because of inaccurate prediction of responsiveness in patients ventilated with low tidal volumes (<8 ml/kg) ( 34 , 35 ). The ability of ΔV peak , PPV, SPV, PVI, and SVV PCA to predict the response to a fluid challenge has been assessed in anesthetized mechanically ventilated dogs ( 12 16 , 18 , 21 , 22 ).…”
Section: What Is Fluid Responsiveness and How Can It Be Assessed?mentioning