1997
DOI: 10.1016/s0378-4347(96)00368-4
|View full text |Cite
|
Sign up to set email alerts
|

Use of metal chelate affinity chromatography and membrane-based ion-exchange as clean-up procedure for trace residue analysis of tetracyclines in animal tissues and egg

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
33
1
1

Year Published

2000
2000
2015
2015

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 61 publications
(35 citation statements)
references
References 11 publications
0
33
1
1
Order By: Relevance
“…Moreover, most chemical methods require a complicated sample preparation step. Commonly, cleanup methods are based on solid-phase extraction (Furusawa, 1999;Cherlet et al, 2003;Cliquet et al, 2003) or metal chelate affinity chromatography (Croubels et al, 1997). These methods are time-consuming and costly, and require large sample volumes.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, most chemical methods require a complicated sample preparation step. Commonly, cleanup methods are based on solid-phase extraction (Furusawa, 1999;Cherlet et al, 2003;Cliquet et al, 2003) or metal chelate affinity chromatography (Croubels et al, 1997). These methods are time-consuming and costly, and require large sample volumes.…”
Section: Introductionmentioning
confidence: 99%
“…Isolation of TCs from tissues is usually followed by an SPE clean-up procedure using RP materials and metal blocking agents [9, 16 -18, 24, 25, 28, 30], while liquid -liquid extraction is rarely used [16,19,29] as it is time consuming and needs large amounts of organic solvents. Metal chelate affinity chromatography (MCAC) off-and on-line, based on the chelating ability of TCs, as well as exchange extraction membranes, and XAD-2 resins have also been employed as purification methods [13,26,28,31]. Disadvantages of these procedures are mainly focused on their complication and their poor recoveries, so that in most cases an extra SPE step is demanded.…”
Section: Introductionmentioning
confidence: 99%
“…In different studies the use of polymeric (8,14,15,29), phenyl (23), C8-bonded silica (2), or C18 analytical columns to analyse TCs in animal tissues (4, 7) have been presented. Polymeric columns were chosen to eliminate interaction of silanols and trace metals, but Mc Cracken et al (22) obtained less satisfactory results with a polymer column versus a commonly use C8 or C18 analytical column.…”
Section: Discussionmentioning
confidence: 99%
“…As described above, TCs have a chelating ability, which has been used to establish a clean-up method, such as metal chelate affinity chromatography (12,14). However, this method requires complicated procedures and gives poor recovery and reproducibility.…”
Section: Discussionmentioning
confidence: 99%