2013
DOI: 10.1007/978-1-62703-520-0_11
|View full text |Cite
|
Sign up to set email alerts
|

Use of Meso-Scale Discovery™ to Examine Cytokine Content in Microglia Cell Supernatant

Abstract: Cytokine production by activated microglia is one of the hallmarks of inflammatory response in the CNS. The cytokines released by microglia cells can be very different depending on the proinflammatory stimulus. Traditionally, to quantify these different cytokines, the "Sandwich"-enzyme-linked immunosorbent assay (Sandwich-ELISA) has been used. In this chapter we will discuss and describe an improved protocol of the Sandwich-ELISA developed by Meso-Scale Discovery based on an electrochemiluminescence detection … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 4 publications
0
10
0
Order By: Relevance
“…The levels of cytokines were measured using an electrochemi-luminescence-based multi-array method through the Quickplex SQ 120 system (Meso Scale Diagnostics LLC, Rockville, MD) by previously reported methods [ 46 49 ]. In brief, the system utilizes 96-well-based high throughput readout.…”
Section: Methodsmentioning
confidence: 99%
“…The levels of cytokines were measured using an electrochemi-luminescence-based multi-array method through the Quickplex SQ 120 system (Meso Scale Diagnostics LLC, Rockville, MD) by previously reported methods [ 46 49 ]. In brief, the system utilizes 96-well-based high throughput readout.…”
Section: Methodsmentioning
confidence: 99%
“…Compared with the traditional ELISA approach, the MSD platform shows greater sensitivity and is able to reliably detect different proteins across a broad dynamic range of concentrations [20]. The assay is based upon electro-chemiluminescence technology by using specific capture antibodies coated at corresponding spots on an electric wired microplate.…”
Section: Methodsmentioning
confidence: 99%
“…Cytokine proteins in plasma and hippocampal homogenates were quantified using a customized Meso-Scale Discovery (MSD) V-Plex electrochemiluminescence assay for mice, which allows ultralow detection of multiple cytokines in mouse plasma and supernatants [ 44 ]. V-plex plus 96-well plates coated with primary antibodies directed against interleukin (IL)-1β, IL-4, IL-6, and tumor necrosis factor (TNF)-α were used and were treated with the corresponding detecting antibodies, which were prelabeled with SULFO-TAG™ (MSD, Rockville, Maryland, USA).…”
Section: Methodsmentioning
confidence: 99%