2009
DOI: 10.1016/j.ijrefrig.2009.02.004
|View full text |Cite
|
Sign up to set email alerts
|

Use of hydrocarbons as drop-in replacements for HCFC-22 in on-farm milk cooling equipment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 4 publications
0
6
0
Order By: Relevance
“…These performance problems are common in Sardinian sheep dairy farms (diagnosed in 22% of the sample) and do not seem to be related to the age of the MCSs, showing that even old refrigerating systems can work properly with regular maintenance. The refilling of the refrigerant brings the refrigerating circuit back to a good efficiency and decreases the energy consumption up to 8%, especially if replaced with a mixture of propane and ethane [25]. The BII class MCSs that received a refilling (tank Nos.…”
Section: Discussionmentioning
confidence: 99%
“…These performance problems are common in Sardinian sheep dairy farms (diagnosed in 22% of the sample) and do not seem to be related to the age of the MCSs, showing that even old refrigerating systems can work properly with regular maintenance. The refilling of the refrigerant brings the refrigerating circuit back to a good efficiency and decreases the energy consumption up to 8%, especially if replaced with a mixture of propane and ethane [25]. The BII class MCSs that received a refilling (tank Nos.…”
Section: Discussionmentioning
confidence: 99%
“…The use of phase-change materials for low temperature thermal energy storage is another area of research (Oro, et al 2012a(Oro, et al , 2012b(Oro, et al , 2014, while drop-in replacements for HCFCs in on-farm milking equipment has also been investigated (Cleland et al, 2009).…”
Section: Research Related To the Cold Chainmentioning
confidence: 99%
“…The compressor discharge temp of R432A is 14.1-17.3ºC lower than that of R22 whereas the amount of charge for R432A is 50% lower than that of R22 due to its low density. Cleland et al [88] conducted experimental studies on an on-farm milk cooling working with Care-50 [a mixture of propane (R-290) and ethane (R-170)] as an alternative to R22. It was reported that Care-50 reduced energy use by 6-8% and had similar system cooling capacity relative to HCFC-22.…”
Section: Refrigerant Mixturesmentioning
confidence: 99%