2003
DOI: 10.1556/jpc.16.2003.1.12
|View full text |Cite
|
Sign up to set email alerts
|

Use of HPTLC for quantitative evaluation of inulin in food products

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
18
0

Year Published

2004
2004
2017
2017

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(19 citation statements)
references
References 3 publications
1
18
0
Order By: Relevance
“…In particular, instrumental techniques such as high-performance liquid chromatography (HPLC) coupled to either ultraviolet (UV) [4] or mass spectrometric (MS) detection [5], gas chromatography (GC) employing a flame ionization detector [6], thin-layer chromatography-mass spectrometry (TLC-MS) [7], capillary electrophoresis [8], Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) [9] have been employed. Considering the frequency of their use, the methods employing HPLC are dominating, not only because liquid chromatographs represent common laboratory equipment, but they also enable an easy operation with good performance characteristics for caffeine measurements.…”
Section: Introductionmentioning
confidence: 99%
“…In particular, instrumental techniques such as high-performance liquid chromatography (HPLC) coupled to either ultraviolet (UV) [4] or mass spectrometric (MS) detection [5], gas chromatography (GC) employing a flame ionization detector [6], thin-layer chromatography-mass spectrometry (TLC-MS) [7], capillary electrophoresis [8], Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) [9] have been employed. Considering the frequency of their use, the methods employing HPLC are dominating, not only because liquid chromatographs represent common laboratory equipment, but they also enable an easy operation with good performance characteristics for caffeine measurements.…”
Section: Introductionmentioning
confidence: 99%
“…Quantitative evaluation was performed with a flatbed scanner and densitometer. The precision of method for the main inulin fractions was 6%; LOQ varied from 0.1 to 1 μg/per spot, and the linear working range was between 0.5 and 4.0 μg/per spot (Prošek et al 2003).…”
Section: Quantification Of Oligosaccharidesmentioning
confidence: 96%
“…A mixture of aniline-diphenylamine orthophosphoric acid is a very often-used detection reagent (Lee et al 1979;Martinez-Castro and Olano 1981;Anderson et al 2000;Prošek et al 2003;Reiffová and Nemcová 2006;Morlock and Vega-Herrera 2007). A mixture of anisaldehyde-sulfuric acid was used as the detection reagent for the visualization of carbohydrates (Stahl and Glatz 1982).…”
Section: Chemical Detection Reagentsmentioning
confidence: 99%
See 1 more Smart Citation
“…[4]. The TLC method has been carried out by Simonowska, B., who three years later carried out another study using HPTLC method [5][6], anionexchange high-performance liquid chromatography (HPLC) method has been carried out by Zuleta [7] and Enzymatic method has been reported by Korakli, M. [8].…”
Section: Notementioning
confidence: 99%