2009
DOI: 10.1007/s00066-009-2007-7
|View full text |Cite
|
Sign up to set email alerts
|

Use of Gold Markers for Setup in Image-Guided Fractionated High-Dose-Rate Brachytherapy as a Monotherapy for Prostate Cancer

Abstract: Caudad position shifts up to 36 mm were observed. Gold markers represent a valuable tool to ensure setup accuracy and precise dose delivery in fractionated HDR-B monotherapy of prostate cancer.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 26 publications
0
5
0
Order By: Relevance
“…Brachytherapy allows for high-dose delivery within the prostate with sharp dose fall-off to the surrounding structures and sparing of the rectum and urinary bladder [9]. Different fractionation regimens (2-4 fractions), target volumes (tumor volume, prostate capsule, peripheral zone), and doses (3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15) Gy per fraction) have been previously described [3,11,14,15]. The application of brachytherapy needles is performed with the patient in the lithotomy position using spinal anesthesia.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Brachytherapy allows for high-dose delivery within the prostate with sharp dose fall-off to the surrounding structures and sparing of the rectum and urinary bladder [9]. Different fractionation regimens (2-4 fractions), target volumes (tumor volume, prostate capsule, peripheral zone), and doses (3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15) Gy per fraction) have been previously described [3,11,14,15]. The application of brachytherapy needles is performed with the patient in the lithotomy position using spinal anesthesia.…”
Section: Introductionmentioning
confidence: 99%
“…The 3D preplan compensation of the dose distribution is limited because "hot" spots pose an imminent risk of increased toxicity. Since the quality of the implant correlates directly with the precision of needle positioning and the accuracy of target volume definition, additional deviations in needle positioning occur leading to dose failures in areas of the target volume [8,10,21].…”
Section: Introductionmentioning
confidence: 99%
“…As a consequence, over the last few years, a number of alternative methods have been investigated. Optimal setup control would require the implantation of gold fiducial markers [11,13,20], but it is a cumbersome and invasive procedure. Ultrasound-based imaging has been recently introduced, but it may overestimate the daily prostate motion, particularly in the AP direction, negatively impacting prostate dose coverage and rectal sparing [22].…”
Section: Introductionmentioning
confidence: 99%
“…As previously described significant applicator shifts were detected and corrected and these shifts were not associated with the occurrence of GU toxicity [10]. However, we cannot exclude that some applicator shifts were not recognized contributing to impaired dosimetry and subsequently late GU toxicity.…”
Section: Resultsmentioning