2015
DOI: 10.1177/1932296815569573
|View full text |Cite
|
Sign up to set email alerts
|

Use of Fructosyl Peptide Oxidase for HbA1c Assay

Abstract: ARKRAY, Inc developed the world's first automatic glycohemoglobin analyzer based on HPLC (1981). After that, ARKRAY developed enzymatic HbA1c assay "CinQ HbA1c" with the spread and diversification of HbA1c measurement (2007). CinQ HbA1c is the kit of Clinical Chemistry Analyzer, which uses fructosyl peptide oxidase (FPOX) for a measurement reaction. This report mainly indicates the developmental background, measurement principle, and future of the enzymatic method HbA1c reagent.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 8 publications
0
3
0
1
Order By: Relevance
“…Blood samples were collected into two sodium fluoridecontaining blood collection tubes for glucose measurement (Venoject II, Terumo Co., Tokyo, Japan). One was immediately centrifuged and subjected to HbA1c measurement in blood cells by EA (CinQ HbA1c, Arkray, Inc., Kyoto, Japan) [4]. The other sample in a test tube stand was transferred to Arkray Inc. by courier in a refrigerated state, and HPLC-HbA1c and EA-HbA1c were measured the day following blood sample collection.…”
Section: Laboratory Methodsmentioning
confidence: 99%
“…Blood samples were collected into two sodium fluoridecontaining blood collection tubes for glucose measurement (Venoject II, Terumo Co., Tokyo, Japan). One was immediately centrifuged and subjected to HbA1c measurement in blood cells by EA (CinQ HbA1c, Arkray, Inc., Kyoto, Japan) [4]. The other sample in a test tube stand was transferred to Arkray Inc. by courier in a refrigerated state, and HPLC-HbA1c and EA-HbA1c were measured the day following blood sample collection.…”
Section: Laboratory Methodsmentioning
confidence: 99%
“…Since the intact protein HbA 1c is not a substrate for the used FPOX, the fructosamine residue does not react with R1. However, during this incubation step, endogenous fructosamine derivatives present in the blood sample are oxidized and the released hydrogen peroxide is degraded by the HRP present, thereby increasing the specificity of HbA 1c detection later [47]. After addition of reagent 2 (R2), containing a protease and a leuco dye, HbA 1c is enzymatically cleaved by the protease.…”
Section: Enzymatic Oxidative Degradation Of Fructosamine Fru-val-his mentioning
confidence: 99%
“…HbA1c adalah protein terglikasi di mana glukosa melekat pada terminal-N dari rantai β hemoglobin (Yonehara et al, 2015). Kadar HbA1c mewakili kontrol glikemik rata-rata selama 2-3 bulan terakhir (Ryden et al, 2014).…”
Section: Pendahuluanunclassified