1962
DOI: 10.1161/01.res.10.3.505
|View full text |Cite
|
Sign up to set email alerts
|

Use of External Counting Technics In Studies of the Circulation

Abstract: A variety of external counting technics has been used to study the circulation. Brief consideration has been given to some of those concerned with measurement of cardiac output, myocardial and other regional blood flows, and cardiopulmonary volumes, and to those related to the evaluation of vascular shunts. These technics have much in common. They are simple to carry out, require little time to accomplish, and entail little risk for the subject. At the same time, they are to varying extents imprecise… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

1963
1963
1981
1981

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 25 publications
(10 citation statements)
references
References 37 publications
0
10
0
Order By: Relevance
“…The bulk of measurements of flow in the present study were made by the semi-logarithmic re-plot method. Full details of the theory of inert gas clearance techniques for the measurement of tissue blood flow are given in the papers by Conn (1962), Herd et al (1962), Ross et al (1964) and Zierler (1965).…”
Section: Methodsmentioning
confidence: 99%
“…The bulk of measurements of flow in the present study were made by the semi-logarithmic re-plot method. Full details of the theory of inert gas clearance techniques for the measurement of tissue blood flow are given in the papers by Conn (1962), Herd et al (1962), Ross et al (1964) and Zierler (1965).…”
Section: Methodsmentioning
confidence: 99%
“…These methods can be criticized because cellular transport mechanisms rather than flow may be the factor limiting uptake, particularly in studies in which 80 Rb is used (28). However, a comparative study of the 8(i Rb method with metered coronary blood flow showed that the method gives an accurate estimate of directional change in coronary flow, although it tends to underestimate metered flow at high flow rates because of decreased extraction (29).…”
Section: Moirmentioning
confidence: 99%
“…If the emptying of the ventricle is retarded as a manifestation of its failure, the isotope activity in the ventricle persists and this manifests itself by a gradual decline of the descendent part (23). The dilution stage is thus retarded (the ratio according to Donato et al [4] is low).…”
Section: Discussionmentioning