2021
DOI: 10.3390/ani11051350
|View full text |Cite
|
Sign up to set email alerts
|

Use of Electrical Impedance Tomography (EIT) to Estimate Tidal Volume in Anaesthetized Horses Undergoing Elective Surgery

Abstract: This study explores the application of electric impedance tomography (EIT) to estimate tidal volume (VT) by measuring impedance change per breath (∆Zbreath). Seventeen healthy horses were anaesthetised and mechanically ventilated for elective procedures requiring dorsal recumbency. Spirometric VT (VTSPIRO) and ∆Zbreath were recorded periodically; up to six times throughout anaesthesia. Part 1 assessed these variables at incremental delivered VT of 10, 12 and 15 mL/kg. Part 2 estimated VT (VTEIT) in litres from… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 11 publications
(18 citation statements)
references
References 41 publications
0
18
0
Order By: Relevance
“…Tidal impedance variation (TIV; arbitrary units). TIV represents the total ΔZ over one breath and can be used as the EIT surrogate of tidal volume in large animals ( 17 , 18 ).…”
Section: Methodsmentioning
confidence: 99%
“…Tidal impedance variation (TIV; arbitrary units). TIV represents the total ΔZ over one breath and can be used as the EIT surrogate of tidal volume in large animals ( 17 , 18 ).…”
Section: Methodsmentioning
confidence: 99%
“…Impedance change has been shown to have a direct relationship with tidal volume (VT) measured by spirometry in cattle, pigs, dogs and horses (39,43,(49)(50)(51). However, there are inconsistencies in the literature in the terms used to describe this variable.…”
Section: Tidal Impedance Variation or Tidal Volume (Tiv Or Eit Respe...mentioning
confidence: 99%
“…It is recommended that the term tidal variation (TIV) is used when the change in impedance is presented in AU, while the term tidal volume (VT EIT ) is used when the change in impedance is converted to units of volume (e.g., L or mL), either using a predefined linear regression line or after calibration using spirometry (49). It should be specified in materials and methods if tidal variation (TIV in AU or tidal volume (VT EIT ) in L or mL estimated from measured Z) is used to estimate gas volume per breath.…”
Section: Tidal Impedance Variation or Tidal Volume (Tiv Or Eit Respe...mentioning
confidence: 99%
See 2 more Smart Citations