2008
DOI: 10.1016/j.ndteint.2007.06.004
|View full text |Cite
|
Sign up to set email alerts
|

Use of capacitive and GPR techniques for the non-destructive evaluation of cover concrete

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
50
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
3
3
3

Relationship

1
8

Authors

Journals

citations
Cited by 113 publications
(52 citation statements)
references
References 17 publications
2
50
0
Order By: Relevance
“…It can be noted that the dependence of the permittivity with temperature seems to be linear and highly dependent on humidity (correlation coefficients R² are close to 1) in accordance with literature (Breysse et al, 2008;Dérobert et al, 2008;Dérobert et al, 2009).…”
Section: Investigation Resultssupporting
confidence: 90%
See 1 more Smart Citation
“…It can be noted that the dependence of the permittivity with temperature seems to be linear and highly dependent on humidity (correlation coefficients R² are close to 1) in accordance with literature (Breysse et al, 2008;Dérobert et al, 2008;Dérobert et al, 2009).…”
Section: Investigation Resultssupporting
confidence: 90%
“…The capacitive technique consists of the measurement of the resonance frequency of an oscillating system between 30 and 35 MHz and between two metallic electrodes disposed on the surface of the studied concrete (Dérobert, 2010;Dérobert, Iaquinta, Klysz, & Balayssac, 2008;Du Plooy et al, 2013;Taillade, Cottineau, & Aubagnac, 2009). It can be considered that these electrodes form with the studied material a dielectric capacitor.…”
Section: Measurement Protocol For the Capacitive Techniquementioning
confidence: 99%
“…Nonetheless, capacitive imaging shows considerable promise for the detection of CUI. It is also worth mentioning that work reported elsewhere indicated that such coplanar capacitive sensors are sensitive to moisture content and water intrusion in non-conducting specimens [30][31][32][33], thus this CI approach also has the potential to detect the presence of water within the insulation layer, as an early warning of CUI. Work including the experiments on industrial specimens with actual Corrosion Under Insulation is currently being performed.…”
Section: Discussionmentioning
confidence: 97%
“…Capacitive sensors have been widely used in many industrial applications, such as proximity/displacement measurement [1,2], material characterization [3][4][5], and non-destructive evaluation (NDE) [6][7][8][9][10]. To design and characterise coplanar capacitive sensors for different measurement requirements, the measurement sensitivity distribution of the CI probe, which describes how effectively each region in the sensing area is contributing to the measured charge signal on the sensing electrode and it can be used to determine the Volume of Influence (VOI) and the imaging ability of a capacitive sensor, need to be studied.…”
Section: Introductionmentioning
confidence: 99%