2004
DOI: 10.1590/s1678-77572004000400016
|View full text |Cite
|
Sign up to set email alerts
|

Use of base metal casting alloys for implant framework: marginal accuracy analysis

Abstract: The original protocol for implant prosthesis recommends the use of a gold framework for acrylic and ceramic prosthesis. However, due to its high cost, the use of alternative alloys is desired. This study compares the marginal accuracy of pre-made cylinders versus plastic cylinders cast with two different base metal casting alloys. Five samples each of (1) plastic cylinder cast in cobalt-chromium alloy, (2) plastic cylinder cast in nickel-chromium alloy, and (3) silver-palladium pre-made cylinder (control) were… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
2
1

Year Published

2011
2011
2020
2020

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(15 citation statements)
references
References 7 publications
(5 reference statements)
0
12
2
1
Order By: Relevance
“…Various authors have studied the fit of machined titanium abutments and others cast from different materials such as zirconia, concluding that machined titanium and zirconium oxide produce the best fit (11-13). For this reason, machined titanium components were chosen for this study.…”
Section: Discussionmentioning
confidence: 99%
“…Various authors have studied the fit of machined titanium abutments and others cast from different materials such as zirconia, concluding that machined titanium and zirconium oxide produce the best fit (11-13). For this reason, machined titanium components were chosen for this study.…”
Section: Discussionmentioning
confidence: 99%
“…The procedure that attempts to compensate for shrinkage or deformation, the one-piece casting method, waxing was performed directly on the abutment in polyurethane block 8 . Studies to evaluate the fit of the abutment/prosthesis interface have demonstrated that the precision of unitary metallic structures obtained with prefabricated cylinders is better than that obtained with plastic cylinders 2,14 . However, it should be noted that the care involved in handling multiple prostheses is very different from that involved in handling single ones, and the complexity of the laboratory procedures increases proportionally to the number of fixations involved.…”
Section: Discussionmentioning
confidence: 99%
“…They found values of 5.6±6.4; 11.1±8.2; 8.0±9.3 and 7.0±3.8 respectively. In a similar previous work, Kano, et al 21 (2004) have measured the vertical misfit at interface of premachined standard abutments and plastic burnout abutments cast with NiCr or CoCr alloys and found values ranging from 4.13±4.29 for the former group to 23,18±6.96 to CoCr group and 25,06±7.75 for NiCr group. Their results are in accordance with this work, when suggest that the laboratory procedures can influence implant/ abutment interface.…”
Section: Discussionmentioning
confidence: 72%
“…Among the factors that contribute to screw instability are misfit of the prosthesis 21 , insufficient tightening force 13,14,26 , screw settling 25 biomechanical overload 26 , and differences in screw material or design 19 .…”
Section: Introductionmentioning
confidence: 99%