Use of an Electron Beam Melting Manufactured Titanium Collared Cementless Femoral Stem to Resist Subsidence After Canine Total Hip Replacement

Abstract: A collar on a cementless femoral stem in contact with cortical bone resists subsidence.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

3
63
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 32 publications
(67 citation statements)
references
References 40 publications
3
63
1
Order By: Relevance
“…Because of the retrospective nature of the study, there was variability in the implants used. All dogs were implanted with BioMedtrix BFX implants; however, newer modified versions of the BFX stems were used in some dogs, including the use of a BFX stem with lateral locking bolt in two dogs and a collared stem in another two dogs, both designed to help prevent stem subsidence (Table ) . The only stem complication (subsidence) noted was in a dog with a stem not specifically modified to help prevent subsidence.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Because of the retrospective nature of the study, there was variability in the implants used. All dogs were implanted with BioMedtrix BFX implants; however, newer modified versions of the BFX stems were used in some dogs, including the use of a BFX stem with lateral locking bolt in two dogs and a collared stem in another two dogs, both designed to help prevent stem subsidence (Table ) . The only stem complication (subsidence) noted was in a dog with a stem not specifically modified to help prevent subsidence.…”
Section: Discussionmentioning
confidence: 99%
“…All dogs were implanted with BioMedtrix BFX implants; however, newer modified versions of the BFX stems were used in some dogs, including the use of a BFX stem with lateral locking bolt in two dogs and a collared stem in another two dogs, both designed to help prevent stem subsidence (Table 1). 30,31 The only stem complication (subsidence) noted was in a dog with a stem not specifically modified to help prevent subsidence. Assessment of dogs with pseudoacetabulum treated by THA with no variability in implants used may give a truer reflection of the complication rate associated with these cases.…”
Section: Discussionmentioning
confidence: 99%
“…During the study period, the ingrowth surface of the Biomedtrix acetabular cup was changed from cobalt chromium sintered beads to a titanium electron beam melted (EBM) surface. The EBM surface has a higher coefficient of friction and more closely imitates cancellous bone, improving the stability of the porous‐substrate interface and increasing removal torque . Improvements in implant technology and osseointegration may make cup revision of cementless THR more challenging …”
Section: Discussionmentioning
confidence: 99%
“…The EBM surface has a higher coefficient of friction and more closely imitates cancellous bone, improving the stability of the porous-substrate interface and increasing removal torque. 27,28 Improvements in implant technology and osseointegration may make cup revision of cementless THR more challenging. 28 Aseptic loosening of cemented implants is reportedly more frequent after revision surgery.…”
Section: Discussionmentioning
confidence: 99%
“…The intuitive reason for migration is insufficient initial fixation. Next day full weight‐bearing creates an unknown and variable degree of micromotion that could lead to early implant migration (settle into the bed preparation) and secondary stabilization in the same way as press‐fit femoral stems settle . In a study in man, 25% of 51 hip arthroplasties had a polar gap.…”
Section: Discussionmentioning
confidence: 99%