2005
DOI: 10.1136/qshc.2003.007914
|View full text |Cite
|
Sign up to set email alerts
|

Use of a systematic risk analysis method to improve safety in the production of paediatric parenteral nutrition solutions

Abstract: Background: Until recently, the preparation of paediatric parenteral nutrition formulations in our institution included re-transcription and manual compounding of the mixture. Although no significant clinical problems have occurred, re-engineering of this high risk activity was undertaken to improve its safety. Several changes have been implemented including new prescription software, direct recording on a server, automatic printing of the labels, and creation of a file used to pilot a BAXA MM 12 automatic com… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
102
0
10

Year Published

2010
2010
2020
2020

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 103 publications
(112 citation statements)
references
References 27 publications
(10 reference statements)
0
102
0
10
Order By: Relevance
“…Un impreso de prescripci贸n bien dise帽ado as铆 como la informatizaci贸n de la prescripci贸n pueden disminuir la incidencia de errores y aumentar la eficiencia del procedimiento (2)(3)(4).…”
Section: Prescripci贸nunclassified
See 1 more Smart Citation
“…Un impreso de prescripci贸n bien dise帽ado as铆 como la informatizaci贸n de la prescripci贸n pueden disminuir la incidencia de errores y aumentar la eficiencia del procedimiento (2)(3)(4).…”
Section: Prescripci贸nunclassified
“…La utilizaci贸n de una aplicaci贸n para el c谩lculo, escritura y env铆o de la prescripci贸n ahorrar铆a tiempo y eliminar铆a tareas repetitivas y c谩lculos tediosos por parte del m茅dico, as铆 como la trascripci贸n por parte del farmac茅utico. Todas ellas son tareas que son fuente de error (2,8). Por otro lado, ser铆a recomendable que permita el acceso a ayudas y a alertas, como la verificaci贸n de la idoneidad de la prescripci贸n en funci贸n de est谩ndares definidos por peso y edad o en funci贸n de par谩metros fisicoqu铆micos (estabilidad de la emulsi贸n y riesgo de precipitaci贸n de calcio y fosfato) (9).…”
Section: La Prescripci贸n De Np Es Un Proceso Susceptible De Errores unclassified
“…It has been well regarded as a beneficial and prominent tool in assessing potential failures and preventing their occurrence [6], rendering both qualitative and quantitative measures to prioritize the prohibition order of failures and their effects towards the quality of products/service [7]. Consequently, the execution of FMEA has been long deployed in diverse industries, such as automotive [8][9][10][11], nuclear, electronics [12,13], chemistry [14,15], lead-free solder control plan [16], sugar mill boiler [17], fuel cells [18], paper [19], metal forming [4], tanker equipment [20], waste [21,22], Hazard Analysis and Critical Control Points audition [23], households [24], engineering systems [25], energy plants [26][27][28], medical devices [29], pharmacy [30][31][32], health care services [33][34][35][36][37][38], e-commerce [39], management [40][41][42][43], software [44], electronic paper display [45], and product design [46,47].…”
Section: Introductionmentioning
confidence: 99%
“…3 Compounding these solutions requires experienced personnel (pharmacists and pharmacy technicians) and an adequate environment where microorganisms and air particles are minimized, because of a high risk of error and contamination during compounding, which can lead to serious adverse events and even patient deaths. 3 Automated compounding devices have been purported to reduce the risk of human error and improve the efficiency of compounding compared with manual preparation. 4,5 Guidelines have been published for the use of automated compounders in the preparation of PN.…”
Section: Introductionmentioning
confidence: 99%