Use of a Novel Penetrating, Sutureless Anastomotic Device in Arterial Microvascular Anastomoses

Abstract: The advent of microsurgery and microvascular anastomosis has helped to alter the treatment of many traumatic defects as well as revolutionize the reconstructive options after extirpative surgery. These procedures, however, continue to be technically demanding and intensive. In addition, increased ischemia and operative times are known to raise complications in microsurgery, particularly in older patients. The nitinol U-clip (Medtronic, Inc., Minneapolis, MN) is a new penetrating clip applied in an interrupted … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 28 publications
0
6
0
Order By: Relevance
“…There has been some limited reporting of this clipping system in coronary artery bypass surgery but very little in reconstructive microsurgery. A case report,53 and a series of three cases have reported generally rapid anastomoses with a reduced learning curve over other mechanical anastomotic aides 54…”
Section: Resultsmentioning
confidence: 99%
“…There has been some limited reporting of this clipping system in coronary artery bypass surgery but very little in reconstructive microsurgery. A case report,53 and a series of three cases have reported generally rapid anastomoses with a reduced learning curve over other mechanical anastomotic aides 54…”
Section: Resultsmentioning
confidence: 99%
“…As an alternative to sutures, nitinol and titanium clips which are crimped in an interrupted pattern to anchor vessel ends have been developed . The average reported time to complete anastomosis for both ends of a vascular graft ranges from 14 to 18 min . Alternatives to anastomosis clips, such as stapling cartridges and ring pin staples, use a minimal number of components to complete anastomosis with a single crimping motion but require an intricate loading process which extend the average procedure from 14 to 30 min …”
Section: Discussionmentioning
confidence: 99%
“…6,31 The average reported time to complete anastomosis for both ends of a vascular graft ranges from 14 to 18 min. 6,[31][32][33] Alternatives to anastomosis clips, such as stapling cartridges and ring pin staples, use a minimal number of components to complete anastomosis with a single crimping motion but require an intricate loading process which extend the average procedure from 14 to 30 min. 7,30,34 In contrast, the average length to perform a doublesided anastomosis using the silk devices designed here was approximately 1 min.…”
Section: Discussionmentioning
confidence: 99%
“…It has, however, been compared favorably to other mechanical anastomotic aides in a small series. 51 The results regarding the VCS clip applicator are summarized in Table 2.…”
Section: Autosuturementioning
confidence: 99%