2009
DOI: 10.1021/es902785c
|View full text |Cite
|
Sign up to set email alerts
|

Use of a Nonnegative Constrained Principal Component Regression Chemical Mass Balance Model to Study the Contributions of Nearly Collinear Sources

Abstract: In this study, a nonnegative constrained principal component regression chemical mass balance (NCPCRCMB) model was used to solve the near collinearity problem among source profiles for source apportionment. The NCPCRCMB model added the principle component regression route into the CMB model iteration. The model was tested with the synthetic data sets, which involved contributions from eleven actual sources, with a serious near collinearity problem among them. The actual source profiles were randomly perturbed … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
27
0
1

Year Published

2011
2011
2015
2015

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 51 publications
(31 citation statements)
references
References 26 publications
(54 reference statements)
3
27
0
1
Order By: Relevance
“…Based on our previous works and other related studies (Shi et al, 2009;Xue et al, 2010;Tian et al, 2013a;Zhao et al, 2013a, b), the PM 2.5 and PM 10 (24 h samples) were simultaneously collected on quartz-fibre filters and polypropylenefibre filters using medium-volume air samplers (TH-150) at a flow rate of 100 L min −1 . The detailed information for the sampling and quality assurance/quality control (QA/QC) are available in the Supplement.…”
Section: Samplingmentioning
confidence: 99%
See 1 more Smart Citation
“…Based on our previous works and other related studies (Shi et al, 2009;Xue et al, 2010;Tian et al, 2013a;Zhao et al, 2013a, b), the PM 2.5 and PM 10 (24 h samples) were simultaneously collected on quartz-fibre filters and polypropylenefibre filters using medium-volume air samplers (TH-150) at a flow rate of 100 L min −1 . The detailed information for the sampling and quality assurance/quality control (QA/QC) are available in the Supplement.…”
Section: Samplingmentioning
confidence: 99%
“…Blanks and duplicate sample analyses were performed for nearly 10 % of the samples. The pretreatment procedure, chemical analysis and QA/QC are described in detail in the Supplement and refer to our previous works and other related studies (Bi et al, 2007;Shi et al, 2009;Wu et al, 2009;Kong et al, 2010;Xue et al, 2010;Zhao et al, 2013a, b).…”
Section: Chemical Analysismentioning
confidence: 99%
“…The principle of CMB model had been described in lots of literature (Hopke, 2003;Shi et al, 2009). In this work, only the principle of CMB-Iteration model is presented, considering the length of the paper.…”
Section: Cmb-iteration Modelmentioning
confidence: 99%
“…Enough blank tests (nearly 10% of samples) were conducted and used to correct corresponding data. The pre-treatment procedure, chemical analysis can be referred to our previous works and other related studies (Bi et al, 2007;Kong et al, 2010;Shi et al, 2009;Tian et al, 2014). Fig.…”
Section: Analysis Of Samplesmentioning
confidence: 99%
“…Therefore, confirming the optimum concentrations of coating solutions before sampling PM 2.5 using HDS is essential, especially in China where the atmospheric concentrations of particulate matter are much higher. Despite of the existence of sampling artifacts, samplers without denuders and back-up filters are still widely used because of the cost-effective equipment and convenient operation (Louie et al, 2005;Shi et al, 2009;Tian et al, 2014).…”
Section: Introductionmentioning
confidence: 99%