2019
DOI: 10.1016/j.ceca.2019.05.002
|View full text |Cite
|
Sign up to set email alerts
|

Use of a microelectrode array to record extracellular pacemaker potentials from the gastrointestinal tracts of the ICR mouse and house musk shrew (Suncus murinus)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
15
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(18 citation statements)
references
References 45 publications
2
15
0
Order By: Relevance
“…Responses are plotted as median with individual values plotted. Friedman's test/Dunn's test comparing responses to incremental concentrations of atropine to the response to neostigmine in the presence of TTX; *P < 0.05 corpus ($6-8/min; Kim et al, 2003;Liu et al, 2019;Worth et al, 2015) and antrum ($3-4/min; Forrest et al, 2006;Hwang et al, 2016;Kim et al, 2003;Sanders, 2020), and also the contraction frequency in antrum circular muscle (3.6 ± 0.5 c.p.m. ;Hwang et al, 2019).…”
Section: Discussionmentioning
confidence: 99%
“…Responses are plotted as median with individual values plotted. Friedman's test/Dunn's test comparing responses to incremental concentrations of atropine to the response to neostigmine in the presence of TTX; *P < 0.05 corpus ($6-8/min; Kim et al, 2003;Liu et al, 2019;Worth et al, 2015) and antrum ($3-4/min; Forrest et al, 2006;Hwang et al, 2016;Kim et al, 2003;Sanders, 2020), and also the contraction frequency in antrum circular muscle (3.6 ± 0.5 c.p.m. ;Hwang et al, 2019).…”
Section: Discussionmentioning
confidence: 99%
“…Electrical recordings were performed using an MEA, as previously described ( Liu et al, 2019 ). In brief, intact full-thickness tissue segments of the antrum, duodenum, ileum and colon were isolated from the adult male shrews (55–75 g) and incubated in Kreb’s medium (in mM: NaCl, 115; KCl, 4.7; KH 2 PO 4 , 1.2; MgSO 4 .7H 2 O, 1.2; CaCl 2 .2H 2 O, 2.5; glucose, 10; NaHCO 3 , 25; sparged with 95%/5% oxygen/carbon dioxide.…”
Section: Methodsmentioning
confidence: 99%
“…Raw data were recorded using MC_Rack, V4.6.2 (Multichannel Systems, Germany) and imported into Spike 2 ® (Version 8.1, Cambridge Electronic Design, United Kingdom) for temporal analysis and into MATLAB (2016a, MathWorks) for spatial-temporal analysis, as previously described ( Liu et al, 2019 ). In brief, a second-order Butterworth lowpass IIR filter at 100 Hz was applied to the raw data, which was then down-sampled to 100 Hz.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations