2013
DOI: 10.1039/c3em30935e
|View full text |Cite
|
Sign up to set email alerts
|

Use of a highly sensitive recombinant hepatoma cell method to determine dioxin concentrations in samples of fish and crab from a hotspot area

Abstract: A new and easy fast-screening test (the Ad-DR (adenoviral vector-dioxin response) bioassay) for dioxins in biological samples from highly dioxin-contaminated areas was developed. The aryl-hydrocarbon-receptor (AhR) reporter system was utilized to transport a dioxin-responsive-element (DRE) via an adenovirus vector into rat hepatoma (H4IIE) cells before each experiment; these DRE-H4IIE cells were utilized in the Ad-DR bioassay. Biological extracts were simultaneously analyzed by the Ad-DR bioassay and high reso… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 30 publications
(26 reference statements)
1
5
0
Order By: Relevance
“…Therefore, a highly sensitive recombinant hepatoma cell method (adenoviral vector-dioxin response (Ad-DR) bioassay), which takes much less time, was also adopted to analyze the PCDD/F concentration of specimens. Ad-DR bioassay has been demonstrated as a possible screening tool and has been shown to produce results consistent with those of high-resolution gas chromatography/ high-resolution mass spectrometry (HRGC/HRMS) (Chao et al, 2010(Chao et al, , 2012Lin et al, 2013). This study confirms the feasibility of this quick method for ash samples.…”
Section: Introductionsupporting
confidence: 68%
See 3 more Smart Citations
“…Therefore, a highly sensitive recombinant hepatoma cell method (adenoviral vector-dioxin response (Ad-DR) bioassay), which takes much less time, was also adopted to analyze the PCDD/F concentration of specimens. Ad-DR bioassay has been demonstrated as a possible screening tool and has been shown to produce results consistent with those of high-resolution gas chromatography/ high-resolution mass spectrometry (HRGC/HRMS) (Chao et al, 2010(Chao et al, , 2012Lin et al, 2013). This study confirms the feasibility of this quick method for ash samples.…”
Section: Introductionsupporting
confidence: 68%
“…According to the linear regressions, the BEQ can serve as an index of PCDD/F emission to quickly predict the approximate PCDD/F concentration for HRGC/HRMS analysis. In addition, the PCDD/F distributions for I-TEQs and BEQs have similar profiles (Chao et al 2010(Chao et al , 2012Lin et al, 2013). Therefore, Ad-DR bioassay may be a promising method for investigating PCDD/F emission behavior with reduced time and the cost.…”
Section: Pcdd/f Distribution Of Output Materialsmentioning
confidence: 95%
See 2 more Smart Citations
“…The quality assurance/quality control (QA/QC) of this effective extraction and cleanup system meets the criteria in U.S. EPA Method 1613B, 1668A, 1614, 4425, and 4435 as well as the Taiwanese EPA Method [13]. The fast extraction approach coupled with cleanup processes have been applied to various matrices, including soils, sediments, and fish [25,26,40]. …”
Section: Introductionmentioning
confidence: 99%