2004 Proceedings. 54th Electronic Components and Technology Conference (IEEE Cat. No.04CH37546)
DOI: 10.1109/ectc.2004.1320278
|View full text |Cite
|
Sign up to set email alerts
|

Use-condition-based cyclic bend test development for handheld components

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(11 citation statements)
references
References 4 publications
0
11
0
Order By: Relevance
“…And the cyclic bending test also was started, because the use of mobile device has been increased. As a result of previous study, thermal cycling behavior of solder joints was revealed brightly [1][2][3][4] and bending fatigue behavior has been uncovered [5][6][7]. But the relationship between thermal and bending fatigue behavior was not discovered yet.…”
Section: Introductionmentioning
confidence: 87%
“…And the cyclic bending test also was started, because the use of mobile device has been increased. As a result of previous study, thermal cycling behavior of solder joints was revealed brightly [1][2][3][4] and bending fatigue behavior has been uncovered [5][6][7]. But the relationship between thermal and bending fatigue behavior was not discovered yet.…”
Section: Introductionmentioning
confidence: 87%
“…Four-point bending test is widely used because it is suitable for testing large sample size of packages at similar loading condition (bending moments) between the inner load span regions. All the existing bend tests from reported literature [3][4][5] were conducted at room temperature (25 o C) and were for tin-lead (Sn-Pb) solder joints. Typical thermal cycling reliability test from -40 o C to 125 o C was commonly used in industries and research areas to investigate the thermal fatigue reliability for soldered electronic assembly.…”
Section: Introductionmentioning
confidence: 99%
“…The support span of 100mm and load span of 70mm (see Fig. 1 So far, reported bend tests from the literature [1][2][3][4] were conducted at room temperature (25 o C) and there is lack of 1-4244-0152-6/06/$20.00 ©2006 IEEE data for lead-free solder joints. In this study, four-point cyclic bend tests with frequency of 1Hz were conducted for leadfree specimen at room temperature and high temperature of 125 o C to investigate high temperature effect on bending fatigue failure.…”
Section: Cyclic Bend Test and Analysismentioning
confidence: 98%
“…Skipor and Leicht [8] developed a bending fatigue model for PBGA SnPb solder joint using inelastic strain as damage parameter. Mercado et al [3] proposed a total energy-based bending fatigue model for CSP with eutectic SnPb solder. All bending fatigue models were developed at room temperature from literatures.…”
Section: Bending Fatigue Model Development For Sac Soldermentioning
confidence: 99%
See 1 more Smart Citation