2012
DOI: 10.5334/jbr-btr.88
|View full text |Cite
|
Sign up to set email alerts
|

US findings for chronic lateral epicondylitis.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

4
17
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(22 citation statements)
references
References 7 publications
(16 reference statements)
4
17
0
Order By: Relevance
“…Our results for the accuracy of power Doppler MSUS to detect neovascularization (Table 3) are aligned with previous reports for sensitivity (57%-81%) but are noticeably lower than previously reported values for specificity (98%-100%) (12,34). However, estimates of specificity from the two previous studies may have been inflated by the failure to blind the sonographer, which may cause bias in selecting images and interpretation.…”
Section: Discussionsupporting
confidence: 89%
See 2 more Smart Citations
“…Our results for the accuracy of power Doppler MSUS to detect neovascularization (Table 3) are aligned with previous reports for sensitivity (57%-81%) but are noticeably lower than previously reported values for specificity (98%-100%) (12,34). However, estimates of specificity from the two previous studies may have been inflated by the failure to blind the sonographer, which may cause bias in selecting images and interpretation.…”
Section: Discussionsupporting
confidence: 89%
“…Previous studies have reported findings for power Doppler and grayscale MSUS separately (10,26,27) and in combination (12,34). Our results for the accuracy of power Doppler MSUS to detect neovascularization (Table 3) are aligned with previous reports for sensitivity (57%-81%) but are noticeably lower than previously reported values for specificity (98%-100%) (12,34).…”
Section: Discussionsupporting
confidence: 87%
See 1 more Smart Citation
“…Separate analysis on studies which added sonographic probe-induced tenderness [24,32], increased blood flow on common extensor origin [40] and those studies which only used provocation tests as part of the reference standard were performed. Studies whose diagnostic sensitivity and specificity cannot be pooled were labeled as not applicable.…”
Section: Resultsmentioning
confidence: 99%
“…1 and 2). In cases with tennis elbow, there are typical findings with hypoechogenic areas in the common extensor origin with high blood flow seen on Doppler examination (Obradov and Anderson 2012). The limitation of the ultrasound examination is the experience of the operator.…”
Section: Radiographic Featuresmentioning
confidence: 99%