2002
DOI: 10.1148/radiol.2222010667
|View full text |Cite
|
Sign up to set email alerts
|

Urinary Tract Abnormalities: Initial Experience with Multi–Detector Row CT Urography

Abstract: Multi-detector row CT urography is a useful method for detecting urinary tract abnormalities.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
136
0
4

Year Published

2004
2004
2019
2019

Publication Types

Select...
7
3

Relationship

3
7

Authors

Journals

citations
Cited by 263 publications
(143 citation statements)
references
References 17 publications
3
136
0
4
Order By: Relevance
“…12 The radiation exposure of low-dose unenhanced CT is only slightly higher than KUB radiography and significantly lower than regular-dose unenhanced CT (1-1.9 v. 0.5-1 v. 4.5-5 mSv, respectively). 16,24,25 Lowdose unenhanced CT appears to have emerged as the imaging modality of choice given its very low radiation, diagnostic performance similar to that of regular-dose unenhanced CT, and significantly better diagnostic performance than KUB/ultrasonography. 17 Finally, although the population with the greatest concerns regarding radiation exposure is women, this also appears to be the population with the highest rate of alternative diagnosis.…”
Section: Discussionmentioning
confidence: 99%
“…12 The radiation exposure of low-dose unenhanced CT is only slightly higher than KUB radiography and significantly lower than regular-dose unenhanced CT (1-1.9 v. 0.5-1 v. 4.5-5 mSv, respectively). 16,24,25 Lowdose unenhanced CT appears to have emerged as the imaging modality of choice given its very low radiation, diagnostic performance similar to that of regular-dose unenhanced CT, and significantly better diagnostic performance than KUB/ultrasonography. 17 Finally, although the population with the greatest concerns regarding radiation exposure is women, this also appears to be the population with the highest rate of alternative diagnosis.…”
Section: Discussionmentioning
confidence: 99%
“…Cumulative evidence from a number of studies suggests that three-phase CT scan exposes patients to approximately two to three times as much radiation as approximately 12 plain film radiographs (though not that many be required) taken during the course of intravenous pyelography (IVP). [97,98,99] More advanced CT protocols, namely multiphase protocols, have made this issue of more significant concern. Possibilities for limiting radiation in these studies include eliminating a phase (which may then limit examination accuracy) or reducing mA during some of the phases of the study.…”
Section: Imaging Modalitiesmentioning
confidence: 99%
“…A TC por multidetectores ("multislice") tem sido recentemente apresentada como opção diagnóstica (25,26) . Tack et al (27) avaliaram 106 pacientes com suspeita de có-lica renal por este método, sem a utilização de meio de contraste oral ou venoso.…”
Section: Outras Modalidades Diagnósticasunclassified