2016
DOI: 10.1016/j.vascn.2016.08.004
|View full text |Cite
|
Sign up to set email alerts
|

UPLC-MS/MS method for simultaneous determination of cyclophosphamide, docetaxel, doxorubicin and 5-fluorouracil in surface samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
25
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(25 citation statements)
references
References 13 publications
0
25
0
Order By: Relevance
“…The development of chromatographic methods for simultaneous analysis of polar and non-polar compounds has piqued the interest of the international scientific community (38), including our research group. More specifically, some authors (13)(14)(15)21) have proposed LC methods for 5-FU resolution via a C18 stationary phase combining hydrophobic and polar selectivity. Since our goal was to analyse as many ADs as possible at the same time, given that cancer treatments often include more than one cytotoxic drug and that this increases the probability of having at least one positive finding, we preferred to use two LC columns: one for hydrophobic cytostatic drugs and one for the hydrophilic ones.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The development of chromatographic methods for simultaneous analysis of polar and non-polar compounds has piqued the interest of the international scientific community (38), including our research group. More specifically, some authors (13)(14)(15)21) have proposed LC methods for 5-FU resolution via a C18 stationary phase combining hydrophobic and polar selectivity. Since our goal was to analyse as many ADs as possible at the same time, given that cancer treatments often include more than one cytotoxic drug and that this increases the probability of having at least one positive finding, we preferred to use two LC columns: one for hydrophobic cytostatic drugs and one for the hydrophilic ones.…”
Section: Discussionmentioning
confidence: 99%
“…In the case of cytotoxic ADs, monitoring surface contamination in hospital environments usually involves wipe tests as a simple way to indirectly assess dermal occupational exposure (12). However, most of the monitoring (13)(14)(15)(16)(17)(18)(19)(20) is focused on no more than five ADs among the following drugs: CP, MT, iphosfamide (IP), paclitaxel (PTX), doxorubicin (DXR), 5-fluorouracyl (5-FU), docetaxel (DTX), epirubicin (EPI), and gemcitabine (GEM). Only a few (21)(22)(23) have expanded the range from seven to ten [5-FU, PTX, CP, IP, MT, GEM, DXR, EPI, vincristine (VNC), vinblastine (VNB), docetaxel (DTX), etoposide (ETP), cytarabine (CTB), irinotecan (IRT), oxaliplatin, and vindesine].…”
mentioning
confidence: 99%
“…Particularly, the chromatography of 5-FU on surface samples, of which more than 400 kg are being administered in Italy each year and 8 t in Germany, has aroused interest in the scientific community. Some authors [23,30,31] proposed LC-MS/MS methods for efficient 5-FU resolution by using Phenomenex Kinetex Biphenyl, Agilent Pursuit XRs Ultra, or Shimadzu SHIM-PACK XR-ODC C18 columns.…”
Section: Discussionmentioning
confidence: 99%
“…In this same line, da Silva et al [71] developed an UPLC-MS/ MS method for the simultaneous determination of DTX, cyclophosphamide, doxorubicin, and 5-fluorouracil in order to evaluate the contact of workers exposed to these antineoplastic drugs. Chromatographic separation was done using a SHIM-PACK XR-ODC-C 18 column (100 mm £ 3.0 mm i.d.…”
Section: Methodsmentioning
confidence: 99%