2020
DOI: 10.1002/mp.14249
|View full text |Cite
|
Sign up to set email alerts
|

Update of the CLRP TG‐43 parameter database for low‐energy brachytherapy sources

Abstract: To update the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database for low-energy (≤50 keV) photon-emitting low-dose rate (LDR) brachytherapy sources utilizing the open-source EGSnrc application egs_brachy rather than the BrachyDose application used previously for 27 LDR sources in the 2008 CLRP version (CLRPv1). CLRPv2 covers 40 sources (103 Pd, 125 I, and 131 Cs). A comprehensive set of TG-43 parameters is calculated, including dose-rate constants, radial dose functions with functiona… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
68
0
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 23 publications
(70 citation statements)
references
References 68 publications
1
68
0
1
Order By: Relevance
“…Dose is scored in a 51×51×51array of (0.05 cm) 3 voxels spanning the eye region, extending from −1.275 cm x,0.166667em0.166667emy1.275 cm, and from −0.075 cm z2.475 cm (voxels centered along the plaque's central axis). For voxels that overlap with the plaque, dose is scored only in the portion of the voxel not occupied by the plaque, necessitating application of egs_brachy's voxel volume correction for which 109random points/cm 3 are used 16,18 …”
Section: Acquisition and Validation Methodsmentioning
confidence: 99%
“…Dose is scored in a 51×51×51array of (0.05 cm) 3 voxels spanning the eye region, extending from −1.275 cm x,0.166667em0.166667emy1.275 cm, and from −0.075 cm z2.475 cm (voxels centered along the plaque's central axis). For voxels that overlap with the plaque, dose is scored only in the portion of the voxel not occupied by the plaque, necessitating application of egs_brachy's voxel volume correction for which 109random points/cm 3 are used 16,18 …”
Section: Acquisition and Validation Methodsmentioning
confidence: 99%
“…27 The plaque models and associated parameters are summarized in table 1 with pa- Table 1 rameters/dimensions defined in figure 1; the online CLRP EPv2 database contains diagrams and 131 Cs Isoray model CS-1 Rev2 ® . 18,30 For BEBIG plaques, the ophthalmic 125 I BEBIG IsoSeed ® I-125 (I25.S16) is used which is geometrically identical to the I25.S06 but has higher activity for use in ophthalmologic oncology. 18,31 The egs brachy models of these seeds were recently developed and benchmarked as part of updated 2020 CLRP TG-43v2 database.…”
Section: Iia Monte Carlo Simulations Of Eye Plaquesmentioning
confidence: 99%
“…18,30 For BEBIG plaques, the ophthalmic 125 I BEBIG IsoSeed ® I-125 (I25.S16) is used which is geometrically identical to the I25.S06 but has higher activity for use in ophthalmologic oncology. 18,31 The egs brachy models of these seeds were recently developed and benchmarked as part of updated 2020 CLRP TG-43v2 database. 18 Photons are initialized within the seeds according to the NNDC spectra 32 for 103 Pd and 131 Cs seeds, and for 125 I from the NCRP report 58, 33 all consistent with CLRP TG43v2 database.…”
Section: Iia Monte Carlo Simulations Of Eye Plaquesmentioning
confidence: 99%
See 2 more Smart Citations