2012
DOI: 10.1134/s1061934812090043
|View full text |Cite
|
Sign up to set email alerts
|

Up-to-date methods for the determination of rhenium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
0
1

Year Published

2014
2014
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(16 citation statements)
references
References 36 publications
0
13
0
1
Order By: Relevance
“…The interfering ions were investigated at a fixed concentration of 1 mM, which is a hundred times in excess compared to that of ReO 4 ions. The selectivity coefficient (log k (i,j) amp ) for all the interfering anions studied are listed in Table 2 calculated using the Eq (7) [37]: (7), where i and j correspond to the ReO 4…”
Section: Amperometric Reo 4 Ion Selective Sensors For Real Sample Anamentioning
confidence: 99%
See 1 more Smart Citation
“…The interfering ions were investigated at a fixed concentration of 1 mM, which is a hundred times in excess compared to that of ReO 4 ions. The selectivity coefficient (log k (i,j) amp ) for all the interfering anions studied are listed in Table 2 calculated using the Eq (7) [37]: (7), where i and j correspond to the ReO 4…”
Section: Amperometric Reo 4 Ion Selective Sensors For Real Sample Anamentioning
confidence: 99%
“…The content of rhenium in rhenium-containing raw materials varies in a wide range of concentrations -from 10 -7 to tens of weight percent. This leads to the creation and improvement of methods for its analytical control in different materials [7].…”
Section: Introductionmentioning
confidence: 99%
“…Such studies demonstrate the usefulness of ICP-MS as an alternative to traditional but slower radiometric techniques. The use of high-efficiency cones and desolvating nebulisers allowed the 143 Nd/ 144 Nd ratio to be determined on trace levels (1-5 ng) of Nd. 113 Used in conjunction with a high-yield column preconcentration step, the long term measurement precision of the 143 Nd/ 144 Nd ratio was (AE0.000016, 2 SD), comparable to that of TIMS analysis.…”
Section: Speciationmentioning
confidence: 99%
“…The use of high-efficiency cones and desolvating nebulisers allowed the 143 Nd/ 144 Nd ratio to be determined on trace levels (1-5 ng) of Nd. 113 Used in conjunction with a high-yield column preconcentration step, the long term measurement precision of the 143 Nd/ 144 Nd ratio was (AE0.000016, 2 SD), comparable to that of TIMS analysis. An anion-exchangeresin-based clean-up method 114 for the measurement of d 34 S required only 2 mg of sample and allowed a method precision of 0.24-0.34& (2s) to be achieved.…”
Section: Speciationmentioning
confidence: 99%
“…Химическая подготовка проб является наиболее сложным и длительным этапом серийных анализов с использованием инструментальных методов аналитического контроля и предусматривает перевод анализируемого объекта в раствор одним из способов: кислотное разложение, спекание, сплавление, электрохимическое растворение и т.д. При этом рений переходит в раствор в виде перренат-ионов, но на этом этапе возможны его потери в виде летучих оксидов, галогенидов и оксигалогенидов [1].…”
Section: Introductionunclassified