Unveiling the compatibility of eugenol with formulation excipients by systematic drug-excipient compatibility studies

Abstract: Background: The drug-excipient compatibility studies were carried out with the possible excipients viz. Tween 80, Carbopol 940, chitosan, sodium alginate, and polycaprolactone (PCL) for their possible use in the formulation of eugenol loaded nanoemulsion gels and nanoparticles. Methods: The eugenol-excipient compatibility studies were carried out by visual observations, differential scanning calorimetry (DSC), infrared spectroscopy (FTIR), and high-performance thin-layer chromatography (HPTLC). Results: No not… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
33
0
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 77 publications
(37 citation statements)
references
References 29 publications
3
33
0
1
Order By: Relevance
“…Thus, physicochemical evaluations have been performed on solid materials in a concentrated condition to force the chemical reaction to take place. DSC DSC has been widely used in monitoring the presence of incompatibility in pharmaceutical preparations (22)(23)(24)(25)(26)(27)(28)(29)(30)(31). Compatibility data should be interpreted carefully as lots of deviations from principal laws can be explained.…”
Section: Resultsmentioning
confidence: 99%
“…Thus, physicochemical evaluations have been performed on solid materials in a concentrated condition to force the chemical reaction to take place. DSC DSC has been widely used in monitoring the presence of incompatibility in pharmaceutical preparations (22)(23)(24)(25)(26)(27)(28)(29)(30)(31). Compatibility data should be interpreted carefully as lots of deviations from principal laws can be explained.…”
Section: Resultsmentioning
confidence: 99%
“…The Tween 80 (TW) showed two characteristic peaks at 6.3 • C and 66.4 • C [79,80]. Besides, its flashpoint was observed as an endothermic peak above 150 • C (~175 • C), as specified by the manufacturer (Figure 3b).…”
Section: Samplementioning
confidence: 88%
“…One set of tubes were analyzed as soon as prepared. The second sets of samples were assigned as control samples and stored at 5Âą3°C [13,14]. These samples were evaluated further by FTIR, non-denaturing SDS-PAGE while third sets of samples were stored for isothermal stress studies (IST) at 25°C Âą 2°C/60 Âą 5% RH in dark stability chamber as per ICH guidelines.…”
Section: Preparation Of Physical Mixtures/binary Blendsmentioning
confidence: 99%
“…The binary blends of enzyme and additives subjected for compatibility studies were initially inspected for any visual changes including colour and gas formation [13]. An Absence of any kind of change in each binary blend propounded as possible compatibility of COLG with the selected additives.…”
Section: Visual Observationsmentioning
confidence: 99%