2018
DOI: 10.1021/acs.analchem.8b04322
|View full text |Cite
|
Sign up to set email alerts
|

Untargeted Molecular Discovery in Primary Metabolism: Collision Cross Section as a Molecular Descriptor in Ion Mobility-Mass Spectrometry

Abstract: In this work we have established a collision cross section (CCS) library of primary metabolites based on analytical standards in the Mass Spectrometry Metabolite Library of Standards (MSMLS) using a commercially available ion mobility-mass spectrometer (IM-MS). From the 554 unique compounds in the MSMLS plate library, we obtained a total of 1246 CCS measurements over a wide range of biochemical classes and adduct types. Resulting data analysis demonstrated that the curated CCS library provides broad molecular … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
89
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 82 publications
(95 citation statements)
references
References 51 publications
3
89
1
Order By: Relevance
“…Given the current resolving power (ca. 60; Lu et al, 2018), this drift time ion mobility instrument is able to differentiate isomers with difference in CCS as low as 2% (Nichols et al, 2018). Note that a majority of molecules can be lost in the drift tube during the IM mode due to interactions with nitrogen gas (Lu et al, 2018).…”
Section: Molecular Level Characterization Of Riverine Dommentioning
confidence: 95%
See 1 more Smart Citation
“…Given the current resolving power (ca. 60; Lu et al, 2018), this drift time ion mobility instrument is able to differentiate isomers with difference in CCS as low as 2% (Nichols et al, 2018). Note that a majority of molecules can be lost in the drift tube during the IM mode due to interactions with nitrogen gas (Lu et al, 2018).…”
Section: Molecular Level Characterization Of Riverine Dommentioning
confidence: 95%
“…Yellow oval indicates more extended compounds (less diagenetically altered) from high-flow samples. (Nichols et al, 2018). Therefore, isomer percentage was further defined as:…”
Section: Comparison Of Geometric Configurations and Isomeric Percentamentioning
confidence: 99%
“…Significant efforts have been made to curate large-scale experimental and calculated CCS databases 23 . For example, Baker group 24 and McLean group 25,26 measured chemical standards to construct experimental CCS databases with >1000 CCS values. Nevertheless, these CCS resources are reported in quite different formats, and lack appropriate procedures and tools for data collection, collation, standardization, and sharing.…”
mentioning
confidence: 99%
“…Since its early beginnings in LC-MS-based metabolic phenotyping [19] the potential of IM, especially when combined with the CCS values derived from it, has been obvious, and both are increasingly being used in metabotyping (e.g., [5,6,[8][9][10][11][12]). However, whilst this trend is welcome, and the results obtained here employing the combination of t R , CCS are gratifying, the relatively low number of positive identifications does once again highlight a major problem for LC-MS-based metabolic phenotyping in that it is much easier to detect potential biomarkers than to actually convincingly identify them.…”
Section: Comparison Of the Profiles From Conventional And Rammp-im-msmentioning
confidence: 99%
“…However, as well as this welcome increase in features, incorporation of IM can result in improved MS data as a result of the separation of co-eluting compounds and can also be used to determine the rotationally averaged collision cross section (CCS) of analytes. These CCS values, which represent a characteristic property of a molecule, provide a further means of improving the identification of metabolites detected in metabolic phenotyping studies in addition to MS [8][9][10][11][12].…”
Section: Introductionmentioning
confidence: 99%