2007
DOI: 10.1373/clinchem.2007.086611
|View full text |Cite
|
Sign up to set email alerts
|

Unraveling the Complexity of Circulating Forms of Brain Natriuretic Peptide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…High specificity can minimize the incidence of false positives in device. To investigate the specificity of the drug probe-functionalized RGO-FET nanosensor for the ERα, 350 pM ERα protein and 100 nM nonspecific proteins, BSA (pI = 4.7), PARP1 (pI = 9.3), BNP (pI = 10.95), and AFP (pI = 4.9) were tested using the developed nanosensor. As shown in Figure A, the variation of Dirac point in PARP1, BSA, BNP, and AFP proteins was almost negligible, while a significant shift was found after incubation with the target ERα.…”
Section: Resultsmentioning
confidence: 99%
“…High specificity can minimize the incidence of false positives in device. To investigate the specificity of the drug probe-functionalized RGO-FET nanosensor for the ERα, 350 pM ERα protein and 100 nM nonspecific proteins, BSA (pI = 4.7), PARP1 (pI = 9.3), BNP (pI = 10.95), and AFP (pI = 4.9) were tested using the developed nanosensor. As shown in Figure A, the variation of Dirac point in PARP1, BSA, BNP, and AFP proteins was almost negligible, while a significant shift was found after incubation with the target ERα.…”
Section: Resultsmentioning
confidence: 99%
“…Non-bioactive NT-proBNP exhibited better stability and could exist in plasma for approximately 7 days at room temperature [37]. In contrast to proBNP, BNP is not modified by glycosylation [38]. Seferian et al [39] raised antibodies against a variety of forms of BNP and found that no posttranslational modification of these peptides occurred.…”
Section: Metabolism and Forms Of Bnpmentioning
confidence: 99%
“…The detection mechanism behind the current change upon binding of target molecules for FET based amperometric biosensors can be explained by the gating effect from the surface charges introduced by the target molecules [25,26]. Because the isoelectric point (pI) of BNP used in this experiment is ~5.4 [27], the BNP molecules are negatively charged in a solution with a pH of 7.20. Therefore, the negative charges introduced by the specific binding between BNP and its receptor would lead to carrier accumulation in PANI layer, resulting in an increase in drain current [25].…”
Section: Characterization Of the 2-d Pani Layer And Testing Systemmentioning
confidence: 99%