Unobtrusive Detection of Simulated Orthostatic Hypotension and Supine Hypertension Using Ballistocardiogram and Electrocardiogram of Healthy Adults

Abstract: Effective management of neurogenic orthostatic hypotension and supine hypertension (SH-OH) due autonomic failure requires a frequent and timely adjustment of medication throughout the day to maintain the blood pressure (BP) within the normal range, i.e., an accurate depiction of BP is a key prerequisite of effective management. One of the emerging technologies that provide one’s circadian and long-term physiological status with increased usability is unobtrusive zero-effort monitoring. In this paper, a zero-ef… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 34 publications
(45 reference statements)
0
4
0
Order By: Relevance
“…The use of similar window size has precedence in other works, including the authors’ previous works where the window size of 7-second for ensemble average was used. The effect of different window sizes has been elaborated in the article [21] .…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The use of similar window size has precedence in other works, including the authors’ previous works where the window size of 7-second for ensemble average was used. The effect of different window sizes has been elaborated in the article [21] .…”
Section: Discussionmentioning
confidence: 99%
“…As such, the beat-to-beat measurements of the Portapres were corrected to match the BP measured by the BpTRU. As the offset correction and synchronization processes were elaborated in previous work [21] , the algorithms were briefly summarized here. The offset correction aimed to shift the entire sequence of BP samples to best match the BP measured by the BpTRU.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Peaks H, I, J, K, and L were detected from the BCG using the following procedure. The maximum value of the BCG wave within 0.3 s after the ECG R-peak was identi ed as the J-peak [17]. The minimum value of the BCG wave between the ECG R-peak and the J-peak was identi ed as the I-negative-peak.…”
Section: Features For Personal Identi Cationmentioning