1994
DOI: 10.1007/bf00122114
|View full text |Cite
|
Sign up to set email alerts
|

Unloaded shortening of skinned mammalian skeletal muscle fibres: effects of the experimental approach and passive force

Abstract: In rabbit, rat and human skinned skeletal muscle fibres the length-time relationship of isotonic releases was determined after maximal Ca2+ activation. Slack test experiments provided information about unloaded conditions. Force clamp experiments of different load were extrapolated for zero load and compared with the slack test data. The course length-time relationship for unloaded conditions was similar using both approaches. However, slack test data showed a triphasic shape which could be fitted by three str… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
48
0

Year Published

1994
1994
2006
2006

Publication Types

Select...
9
1

Relationship

6
4

Authors

Journals

citations
Cited by 44 publications
(49 citation statements)
references
References 32 publications
1
48
0
Order By: Relevance
“…The experimental apparatus and the method for mechanical measurements have been described previously (14). The attachment points for the muscle fibers (active length 铣0.8 -2.5 mm, mean diameter 25-55 m) on the mechanical apparatus were two 铣2-mm-long vertically oriented epoxy carbon fiber needles of 铣100-m tip diameter.…”
Section: Methodsmentioning
confidence: 99%
“…The experimental apparatus and the method for mechanical measurements have been described previously (14). The attachment points for the muscle fibers (active length 铣0.8 -2.5 mm, mean diameter 25-55 m) on the mechanical apparatus were two 铣2-mm-long vertically oriented epoxy carbon fiber needles of 铣100-m tip diameter.…”
Section: Methodsmentioning
confidence: 99%
“…The apparatus and the methods for mechanical measurements have been described previously (Galler and Hilber, 1994). A force sensor AE 801 (SensoNor, Horten, Norway) with a resonance frequency of ~7.5路kHz was used.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 99%
“…AL was plotted against At and linear regression was used to construct a straight line; its slope represents the unloaded shortening velocity. In a separate study, the reliability of Vmax determination was investigated (Galler & Hilber, 1994 velocity measurements based on sarcomere shortening by continuously monitoring the laser diffraction pattern were similar to the results of measurements based on the determination of fibre shortening. The velocity of relative sarcomere shortening varied within a range of + 5% of the corresponding relative fibre shortening.…”
Section: Mechanical Experimentsmentioning
confidence: 99%