Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)
DOI: 10.1109/pcc.2002.998518
|View full text |Cite
|
Sign up to set email alerts
|

Unified power quality conditioner (UPQC): the principle, control and application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
24
0

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 48 publications
(24 citation statements)
references
References 6 publications
0
24
0
Order By: Relevance
“…During the system dynamic conditions, for example, sudden load change, voltage sag, the dc-link feedback controller should respond as fast as possible to restore the dc-link voltage at set reference value, with minimum delay as well as lower overshoot. The proportional-integral (PI)-regulator-based dc-link voltage controller is simple to implement and hence widely used by the researches [12]- [14], [16]- [20], [22], [23], [26]- [33], [36], [38], [40], [42], [46]- [48], [50], [54], [56], [60], [61], [64], [67], [68], [75]- [77], [81]- [84], [88]- [90], [92], [94], [95], [100], [103]- [105], [108], [109], [111]- [114], [116], [117], [119], [122], [124], [126]- [128], [130]- …”
Section: Upqc-state Of the Artmentioning
confidence: 99%
See 1 more Smart Citation
“…During the system dynamic conditions, for example, sudden load change, voltage sag, the dc-link feedback controller should respond as fast as possible to restore the dc-link voltage at set reference value, with minimum delay as well as lower overshoot. The proportional-integral (PI)-regulator-based dc-link voltage controller is simple to implement and hence widely used by the researches [12]- [14], [16]- [20], [22], [23], [26]- [33], [36], [38], [40], [42], [46]- [48], [50], [54], [56], [60], [61], [64], [67], [68], [75]- [77], [81]- [84], [88]- [90], [92], [94], [95], [100], [103]- [105], [108], [109], [111]- [114], [116], [117], [119], [122], [124], [126]- [128], [130]- …”
Section: Upqc-state Of the Artmentioning
confidence: 99%
“…However, the cutoff frequency of these LPF or HPF can affect the dynamic performance of the controller. The UPQC controller based on three-phase pq can be found in [14], [16], [17], [27], [32], [52], [98], [104], [109], [113], [114], and [126], while dq method based controller can be found in [12], [18], [19], [22], [25], [26], [33], [45], [47], [68], [75], [81], [84], [88], [89], [95], [105], [111], [112], [114], [117], [121], [128], [135], [143], [152], [153], [158], [161], and [167]. The original three-phase pq theory exhibits limitations when the supply voltages are distorted and/or unbalanced.…”
Section: Control Techniques For Upqcmentioning
confidence: 99%
“…It is commonly configured with two voltage source converters connected back to back through a DC link capacitor. However, voltage source topology of UPQC has a drawback of slow control of onverter output voltage and no short circuit protection [7]- [8]. In addition, when the active rectifier inside UPQC is used as a power factor corrector, DC bus voltage oscillations appears which makes the control of the series filter output voltage more difficult.…”
Section: Introductionmentioning
confidence: 99%
“…The rotor side converter is connected in shunt like a conventional DFIG. The structure and control of the converters is similar to that of a Unified Power Quality Conditioner (UPQC) [10], [11], hence the new generator is referred as UPQC integrated Wind Generator (UPQC-WG). Similar structure of DFIG has bee reported in [7] and [8].…”
Section: Introductionmentioning
confidence: 99%