2014
DOI: 10.1117/1.jbo.19.12.127002
|View full text |Cite
|
Sign up to set email alerts
|

Underwater near-infrared spectroscopy measurements of muscle oxygenation: laboratory validation and preliminary observations in swimmers and triathletes

Abstract: Abstract. The purpose of this research was to waterproof a near-infrared spectroscopy device (PortaMon, Artinis Medical Systems) to enable NIR measurement during swim exercise. Candidate materials were initially tested for waterproof suitability by comparing light intensity values during phantom-based tissue assessment. Secondary assessment involved repeated isokinetic exercises ensuring reliability of the results obtained from the modified device. Tertiary assessment required analysis of the effect of water i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
27
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 31 publications
(29 citation statements)
references
References 38 publications
(40 reference statements)
2
27
0
Order By: Relevance
“…The MOXY devices report a greater absolute ΔTSI change when compared with the PortaMon at both 30% and 50% MVC. The ΔTSI observed with the current PortaMon devices is similar to that of a previous study, also utilizing a PortaMon device, 8 reporting a ΔTSI reduction of ∼6% and 11% from baseline at 30% and 50% MVC, respectively. Very few studies have utilized the MOXY device, however, of those available, the present ΔTSI at 30% MVC is similar to that observed in the gastrocnemius by supine individuals undertaking a plantar flexion exercise against a 6-kg weight (∼37% versus ∼38%).…”
Section: Comparing Devices During Isometric Exercisesupporting
confidence: 74%
See 1 more Smart Citation
“…The MOXY devices report a greater absolute ΔTSI change when compared with the PortaMon at both 30% and 50% MVC. The ΔTSI observed with the current PortaMon devices is similar to that of a previous study, also utilizing a PortaMon device, 8 reporting a ΔTSI reduction of ∼6% and 11% from baseline at 30% and 50% MVC, respectively. Very few studies have utilized the MOXY device, however, of those available, the present ΔTSI at 30% MVC is similar to that observed in the gastrocnemius by supine individuals undertaking a plantar flexion exercise against a 6-kg weight (∼37% versus ∼38%).…”
Section: Comparing Devices During Isometric Exercisesupporting
confidence: 74%
“…4 In support of this, positive peripheral muscle oxygenation adaptations have been reported as a consequence of cycling sprint interval training, demonstrating that NIRS has the potential to assess the effectiveness of training interventions at the level of the individual athlete. 7 To be effective outside the research laboratory, in an applied exercise environment, there is a requirement for low-cost, portable NIR technology with telemetric capability with the ability to withstand the rigors of sporting environments such as in swimming, 8 short track speed skating, 9 and trail running.…”
Section: Introductionmentioning
confidence: 99%
“…It reflects the dynamic balance between oxygen supply and oxygen demand in the tissue microcirculation [35][36][37]. Previous studies have shown that TSI reflects muscle oxygenation more accurately than HHb [35,38].…”
Section: Near Infrared Spectroscopymentioning
confidence: 99%
“…The technology has been developed in small, wireless instruments showing good intra- and inter-subject reproducibility39, 40 and recently, the TSI signal was found to be stable despite waterproofing and water submersion when a portable CW NIRS device was used during swimming 41 …”
Section: Limitations Of Nirs In Skeletal Musclementioning
confidence: 99%