2007
DOI: 10.1021/jp064333f
|View full text |Cite
|
Sign up to set email alerts
|

Understanding the Reactivity of Oxide-Supported Bimetallic Clusters:  Reaction of NO with CO on TiO2(110)-Supported Pt−Rh Clusters

Abstract: The reactions of CO, NO, and NO with CO have been studied on Pt, Rh, and bimetallic Pt-Rh clusters deposited on TiO 2 (110). The following four cluster surfaces were investigated: 4 ML of Rh, 4 ML of Pt, 2 ML of Rh + 2 ML of Pt (Rh + Pt), and 2 ML of Pt + 2 ML of Rh (Pt + Rh). Scanning tunneling microscopy studies demonstrated that the surfaces exhibited similar cluster sizes and densities, and low-energy ion scattering experiments showed that the surfaces of the bimetallic clusters were Pt-rich (20-30% Rh) re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
64
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 50 publications
(66 citation statements)
references
References 104 publications
2
64
0
Order By: Relevance
“…Experiments were conducted on a rutile TiO 2 (110) crystal (1 cm 9 1 cm 9 0.1 cm, Princeton Scientific Corp.) in two ultrahigh vacuum (UHV) chambers, which have been previously described in detail [10,23,29,30,[32][33][34][35]. LEIS and STM experiments were carried out in the first chamber, which has a base pressure of B5 9 10 -11 Torr, and is equipped with a fine focus ion gun (Omicron, ISE100) and hemispherical analyzer (EA125) for LEIS experiments, as well as a variable-temperature STM (Omicron, [10,23,30,32].…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Experiments were conducted on a rutile TiO 2 (110) crystal (1 cm 9 1 cm 9 0.1 cm, Princeton Scientific Corp.) in two ultrahigh vacuum (UHV) chambers, which have been previously described in detail [10,23,29,30,[32][33][34][35]. LEIS and STM experiments were carried out in the first chamber, which has a base pressure of B5 9 10 -11 Torr, and is equipped with a fine focus ion gun (Omicron, ISE100) and hemispherical analyzer (EA125) for LEIS experiments, as well as a variable-temperature STM (Omicron, [10,23,30,32].…”
Section: Methodsmentioning
confidence: 99%
“…LEIS and STM experiments were carried out in the first chamber, which has a base pressure of B5 9 10 -11 Torr, and is equipped with a fine focus ion gun (Omicron, ISE100) and hemispherical analyzer (EA125) for LEIS experiments, as well as a variable-temperature STM (Omicron, [10,23,30,32]. In the second chamber, soft X-ray photoelectron spectroscopy (sXPS) experiments were conducted on the U12a beamline at the National Synchrotron Light Source at a chamber pressure of B2 9 10 -10 Torr [29,[33][34][35].…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations