2022
DOI: 10.1097/aln.0000000000004282
|View full text |Cite
|
Sign up to set email alerts
|

Understanding Research Methods: Up-and-down Designs for Dose-finding

Abstract: Summary For the task of estimating a target benchmark dose such as the ED50 (the dose that would be effective for half the population), an adaptive dose-finding design is more effective than the standard approach of treating equal numbers of patients at a set of equally spaced doses. Up-and-down is the most popular family of dose-finding designs and is in common use in anesthesiology. Despite its widespread use, many aspects of up-and-down are not well known, implementation is often misguided… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
29
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(29 citation statements)
references
References 68 publications
0
29
0
Order By: Relevance
“…The sample size was calculated according to the stop rule of the up-and-down sequential methodology, in each group, at least six cross overs are needed for accurate EC 50 calculation, and anesthesia trials using Dixon’s up and down method typically have 20–40 patients ( Pace and Stylianou, 2007 ; Feng et al, 2020 ; Oron et al, 2022 ; Zheng et al, 2022 ).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The sample size was calculated according to the stop rule of the up-and-down sequential methodology, in each group, at least six cross overs are needed for accurate EC 50 calculation, and anesthesia trials using Dixon’s up and down method typically have 20–40 patients ( Pace and Stylianou, 2007 ; Feng et al, 2020 ; Oron et al, 2022 ; Zheng et al, 2022 ).…”
Section: Methodsmentioning
confidence: 99%
“…Frontiers in Pharmacology frontiersin.org trials using Dixon's up and down method typically have 20-40 patients (Pace and Stylianou, 2007;Feng et al, 2020;Oron et al, 2022;Zheng et al, 2022).…”
Section: Groupmentioning
confidence: 99%
“…The use of this methodology for dose determination is well established. 15 However, our primary aim was to evaluate whether there exists a dose-response relationship for oxytocin infusion when used as a weight-based regimen. We thus explored whether there was an escalating response with increase in weight-based doses in various groups, and if present, evaluate the ED90 as well.…”
Section: Resultsmentioning
confidence: 99%
“…To further determine the precise ED90 when using weight‐based oxytocin, future studies employing the up‐and‐down sequential allocation method may be conducted. The use of this methodology for dose determination is well established 15 . However, our primary aim was to evaluate whether there exists a dose–response relationship for oxytocin infusion when used as a weight‐based regimen.…”
Section: Discussionmentioning
confidence: 99%
“…Normally distributed continuous variables were compared using the least signifcant diference t-test (LSD-t) or Mann-Whitney U test for nonnormally distributed continuous variables. ED 50 (90% CI) of each group and diferences between groups were calculated with the centered isotonic regression R Language package [14]. A P < 0.05 was considered statistically signifcant.…”
Section: Discussionmentioning
confidence: 99%