Undermining and Ballooning the Proximal Part of the Left Main Coronary Artery Stent Resulting in an Iatrogenic Stent Deformation

Abstract: We present a case of a 52-year-old woman with iatrogenic stent deformation occurred after deployment of the left main (LM) stent due to the unintentional undermining of the proximal part of the LM stent with subsequent balloon dilatation. We tried to crush the deformed part of the LM stent against the left coronary cusp by pushing it with a guiding catheter. The deformed stent was stabilized after stent crushing and the patient didn`t have any cardiovascular events. This case highlights that stent deformation … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 3 publications
0
1
0
Order By: Relevance
“…After post-dilatation with a 4.5 mm non-compliant balloon, and kissing balloon post-dilatation of the LMS bifurcation, the end result within the coronaries was angiographically satisfactory ( Figure 1D ). Once the LMS bifurcation stenting was complete, the avulsed unravelled stent that protruded into the aorta was forced against the superior aortic sinus wall using the tip of the guide catheter which was fixed in the coronary by an inflated semi-compliant balloon (a technique which has previously been described in the literature for protruding stent apparatus 10 ). The procedure was optimized by Intravascular Ultrasound (IVUS) with a 5.0 mm non-compliant balloon to the LMS.…”
Section: Case Presentationmentioning
confidence: 99%
“…After post-dilatation with a 4.5 mm non-compliant balloon, and kissing balloon post-dilatation of the LMS bifurcation, the end result within the coronaries was angiographically satisfactory ( Figure 1D ). Once the LMS bifurcation stenting was complete, the avulsed unravelled stent that protruded into the aorta was forced against the superior aortic sinus wall using the tip of the guide catheter which was fixed in the coronary by an inflated semi-compliant balloon (a technique which has previously been described in the literature for protruding stent apparatus 10 ). The procedure was optimized by Intravascular Ultrasound (IVUS) with a 5.0 mm non-compliant balloon to the LMS.…”
Section: Case Presentationmentioning