2009
DOI: 10.2528/pier09010403
|View full text |Cite
|
Sign up to set email alerts
|

Uncertainty Analysis of the Rational Function Model Used in the Complex Permittivity Measurement of Biological Tissues Using PMCT Probes Within a Wide Microwave Frequency Band

Abstract: Abstract-The PMCT probe, saying, one kind of open-ended coaxial probe adopted widely in microwave coagulation therapy of cancer, has been used to measure the complex permittivity of freshly excised specimens of normal animal tissues. The RFM model for PMCT probe is developed to extract the anticipant permittivity of specimens under test.In addition, the effects of several factors on the measurement results have been considered and discussed, including different temperature and reference materials, as well as t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2010
2010
2013
2013

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 17 publications
0
9
0
Order By: Relevance
“…On the other hand S-parameters computed using the parameters defined by (25) and (26) allow for the easy computation of the ratios of time-averaged power necessary for this work, even when η s and η l are complex. From (25) …”
Section: Appendix a Derivation Of Equations (16)-(18)mentioning
confidence: 99%
“…On the other hand S-parameters computed using the parameters defined by (25) and (26) allow for the easy computation of the ratios of time-averaged power necessary for this work, even when η s and η l are complex. From (25) …”
Section: Appendix a Derivation Of Equations (16)-(18)mentioning
confidence: 99%
“…It should be noted that in study [11] On the other hand, the experimental validation remains very limited by the available techniques for measuring the electromagnetic properties of human tissues, even though lately some approaches have been developed for measurement of permittivity of complex tissues that might be used, to some extent, and for biological tissues [21][22][23][24][25].…”
Section: Ghzmentioning
confidence: 99%
“…Transmission/reflection method is commonly preferred to measure electromagnetic properties of microwave materials [1,2], and the temperatures can be up to 1000 • C [3]. Open-ended coaxial probe method is usually used to measure complex permittivity at high temperatures due to the advantages of broad frequency band and simple measurement process [4][5][6]. But while applied in measuring low-loss materials these methods have high measurement uncertainties.…”
Section: Introductionmentioning
confidence: 99%