2011
DOI: 10.1088/0957-0233/22/10/105104
|View full text |Cite
|
Sign up to set email alerts
|

Uncertainty analysis of the diffusion rate in the dynamic generation of volatile organic compound mixtures

Abstract: The measurement of volatile organic compound (VOC) concentration changes, in the range of 10 ppt–1ppb, is essential in several applications. The World Meteorological Organization has identified a set of VOCs that are critical because of their long-term instability. The measurement of such changes demands generation of reference mixtures at a high accuracy and stability level. The dynamic preparation of gas mixtures based on diffusion is a suitable way of generating accurate reference mixtures, particularly of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
26
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(26 citation statements)
references
References 12 publications
0
26
0
Order By: Relevance
“…Sonic nozzles were chosen instead of thermal mass flow controllers, since these are characterised by a worse calibration stability [14]. Mixtures of VOCs with vapour pressure between 100 Pa and 70 kPa can be generated, keeping the uncertainty of diffusion rate under 1% in the range 1-50 μg•min −1 [10,12]. Acetone was considered in this study as model VOC.…”
Section: Case Study Devicementioning
confidence: 99%
See 3 more Smart Citations
“…Sonic nozzles were chosen instead of thermal mass flow controllers, since these are characterised by a worse calibration stability [14]. Mixtures of VOCs with vapour pressure between 100 Pa and 70 kPa can be generated, keeping the uncertainty of diffusion rate under 1% in the range 1-50 μg•min −1 [10,12]. Acetone was considered in this study as model VOC.…”
Section: Case Study Devicementioning
confidence: 99%
“…Dynamic generation has been proposed as a feasible option to generate standards [6,10]. Dynamic generation is widely used to produce standard materials for VOC at ppm level amount of substance fraction, as defined by ISO 6145 standards [11].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The variability of confluency and its uncertainty due to focus plane variation was calculated as type B, as indicated in [32], assuming a uniform distribution on the range. Significant index values of calculation method and variability contribution to uncertainty were calculated for each image as a ratio between squared contributions [33].…”