1997
DOI: 10.1159/000291822
|View full text |Cite
|
Sign up to set email alerts
|

Umbilical Venous Pulsation Associated with Hypercoiled Cord in Growth-Retarded Fetuses

Abstract: Venous pulsatile flows were detected by pulsed Doppler flow velocimetry throughout the entire umbilical cord in 2 cases of intrauterine growth retardation. Although the hearts of these fetuses had no anomalies and their inferior vena cava flows had normal flow velocity patterns, their cords were severely coiled. In these cases, the pulsatile flow in the umbilical cord vein was caused not by an increase in the preload of the fetal heart, but only by hypercoiling of the umbilical cord. This phenomenon also sugge… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
16
0

Year Published

2003
2003
2013
2013

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 31 publications
(17 citation statements)
references
References 10 publications
(25 reference statements)
1
16
0
Order By: Relevance
“…Furthermore, HCC is associated with a pulsate pattern of the umbilical venous flow velocity waveforms similar to those seen in abnormalities of the fetal central venous flow, secondary to severe circulatory compromise [14,15] . These findings suggest that HCCs may result in compression of the umbilical vein and compromise of the placentofetal blood flow.…”
mentioning
confidence: 88%
“…Furthermore, HCC is associated with a pulsate pattern of the umbilical venous flow velocity waveforms similar to those seen in abnormalities of the fetal central venous flow, secondary to severe circulatory compromise [14,15] . These findings suggest that HCCs may result in compression of the umbilical vein and compromise of the placentofetal blood flow.…”
mentioning
confidence: 88%
“…than in the cord (43/198,22%,30%, (P < 0.001). When pulsation was observed intra-abdominally, the pulsatility was not different from that at the umbilical ring (P = 0.16).…”
Section: Results the Incidence Of Umbilical Venous Pulsation Was Highmentioning
confidence: 87%
“…
ABSTRACT
Objectives
Results The incidence of umbilical venous pulsation was higher at the umbilical ring in the abdominal wall (242/279, 87%, than in the cord (43/198,22%,30%, (P < 0.001). When pulsation was observed intra-abdominally, the pulsatility was not different from that at the umbilical ring (P = 0.16).
…”
mentioning
confidence: 92%
“…Umbilical venous pulsations were observed only at several regions of the umbilical cord in normal fetuses [54], in spite of what was observed over the entire umbilical cord in intra-uterine growth restriction with a hypercoiled umbilical cord [50,51]. These regional umbilical pulsations occurred at points where the umbilical cord winded at large angles (especially more than 60 degrees) or where the umbilical cord was compressed [55].…”
Section: Umbilical Venous Blood Flowmentioning
confidence: 89%