Ultraviolet C radiation influences the robustness of RNA integrity measurement

Abstract: The analytical and clinical validity of analyses of RNA samples destined for clinical diagnosis and therapeutic management is directly impacted by RNA quality. RNA is affected by heat, enzymatic degradation, and Ultraviolet (UV) light. RNA from three eukaryotic cell lines was degraded by heat, RNase, or UV light. RNA integrity values obtained with the benchmark Agilent Bioanalyzer 2100 system were compared with those from the more recent QIAxcel Advanced system. The application of this novel method has allowed… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 31 publications
0
6
0
Order By: Relevance
“…A comparison between the Agilent and Qiaxcel technologies has shown that Qiaxcel is more precise for certain types of RNA samples. 20 All four annual PT programs showed that the Agilent Bioanalyzer is associated with random errors, especially between RINs 4 and 7.…”
Section: Comparison Of Testing Methodsmentioning
confidence: 99%
“…A comparison between the Agilent and Qiaxcel technologies has shown that Qiaxcel is more precise for certain types of RNA samples. 20 All four annual PT programs showed that the Agilent Bioanalyzer is associated with random errors, especially between RINs 4 and 7.…”
Section: Comparison Of Testing Methodsmentioning
confidence: 99%
“…In addition, Unger et al recently demonstrated that the precision of the RIN as an RNA QC test depends on the biochemical or biophysical RNA degradation method used, such as heat, enzymatic, or UV light. Recently, RIS (13) and DV 200 (Illumina Technical Note, Pub. No 470-2013-002) metrics were described in the latest versions of analysis software using QIAxcel Screen Gel software (Ver.…”
Section: Resultsmentioning
confidence: 99%
“…Furthermore, this methodology is unsuitable for highly degraded RNA from FFPE tissues. To overcome these problems, several publications have discussed RNA quality control (QC) tools, for example the RIN (2,3), RNA integrity score (RIS) (13), DV 200 (2014. Expression Analysis of FFPE Samples.…”
Section: Resultsmentioning
confidence: 99%
“…This approach has been applied in other studies 19 , 55 . Comparative studies on different artificial degradative processes for total RNA have shown that thermal degradation changes RNA integrity in a manner that mimics that of degradation by ubiquitous RNases 49 , 52 , 56 .…”
Section: Discussionmentioning