Ultrasound Transmission Spectral Compensation Using Arbitrary Position and Width Pulse Sets

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 9 publications
(13 citation statements)
references
References 23 publications
0
13
0
Order By: Relevance
“…The signal spectrum can be designed to match the required bandwidth, so that all of the energy is used to produce useful frequencies. Furthermore, the spectral content of the ultrasonic signal can be programed [73]. APWP sequences can be considered as a binary analog of an arbitrary waveform.…”
Section: B Apwp Sequence Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…The signal spectrum can be designed to match the required bandwidth, so that all of the energy is used to produce useful frequencies. Furthermore, the spectral content of the ultrasonic signal can be programed [73]. APWP sequences can be considered as a binary analog of an arbitrary waveform.…”
Section: B Apwp Sequence Parametersmentioning
confidence: 99%
“…The beam shape control was limited to a simple optics, aiming for simplicity and small size. The experimental investigation of the ultrasound generation on an acoustic delay line is presented, demonstrating that the spectral content of the ultrasonic signal can be controlled using the APWP sequences, described in [69] and [73].…”
Section: Introductionmentioning
confidence: 99%
“…I-V technique uses current shunt reference resistance which is preferably connected to ground. High side current sensor can be used for I-V or RF I-V measurement setup [27]. But both I-V and ABB require two measurement channels which are usually not available on ultrasonic data acquisition system.…”
Section: A Impedance Measurement Techniquesmentioning
confidence: 99%
“…Single pulse was chosen because it is most popular in ultrasonic NDT systems. Quasichirp is a spread spectrum signal type that is becoming popular both in ultrasonic imaging [27] and impedance measurement. It offers both wide bandwidth and good SNR in measurements at the expense of relatively simple excitation electronics (no linear amplifiers is required).…”
Section: Output Impedance Measurement Systemmentioning
confidence: 99%
“…As the acoustic wave propagating through the interface of inclusions with different acoustic impedance and geometrical size, several phenomena like attenuation, reflection and scattering may occur, based on which three major modalities are categorized: transmission (Svilainis et al, 2018), reflection (Chen et al, 1991) and scattering (Gunarathnee and Chiristidis, 2001). The effect of acoustic scattering only occurs obviously when the size of scatters is similar to the wave length, which is not a common scenario in the application of multiphase flow.…”
Section: Introductionmentioning
confidence: 99%