2000
DOI: 10.1016/s0041-624x(99)00189-4
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasound process tomography system for hydrocyclones

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
16
0

Year Published

2003
2003
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(17 citation statements)
references
References 4 publications
1
16
0
Order By: Relevance
“…Hoekstra et al (1999) utilized LDA to measure fluid velocities and compared their experimental measurements with computational fluid dynamics (CFD) calculations performed using three turbulence models, including the k-e model, RNG k-e model and Reynolds stress transport model. Besides the LDA, other experimental techniques that have been applied towards studies of the hydrocyclone separator system include electrical impedance fault imaging (Williams et al, 1997) and fault photography (Petersen et al, 1996;Williams et al, 1999;West et al, 2000;Schlaberg et al, 2000;Neesse et al, 2004).…”
Section: Introductionmentioning
confidence: 99%
“…Hoekstra et al (1999) utilized LDA to measure fluid velocities and compared their experimental measurements with computational fluid dynamics (CFD) calculations performed using three turbulence models, including the k-e model, RNG k-e model and Reynolds stress transport model. Besides the LDA, other experimental techniques that have been applied towards studies of the hydrocyclone separator system include electrical impedance fault imaging (Williams et al, 1997) and fault photography (Petersen et al, 1996;Williams et al, 1999;West et al, 2000;Schlaberg et al, 2000;Neesse et al, 2004).…”
Section: Introductionmentioning
confidence: 99%
“…West, Jia, and Williams (2000) and Schlaberg, Podd, and Hoyle (2000) were able to use a reflection ultrasound tomography system to study air liquid flows in a hydrocyclone. Deinhammer et al (2008) coupled reflection ultrasound tomography with electrical capacitance tomography to detect air regions in a flowing liquid.…”
Section: Characterisation Of Multiphase Flowsmentioning
confidence: 99%
“…For UST, transducers were placed around a plane near the top of the conical body section (Schlaberg et al, 2000), whilst for the radiography, a medical X-ray camera facility of the University College London was applied. The UST measurements provided a measure of the aircore diameter.…”
Section: Tomographic Verificationmentioning
confidence: 99%