2016
DOI: 10.1590/bjpt-rbf.2014.0186
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasound imaging in women's arm flexor muscles: intra-rater reliability of muscle thickness and echo intensity

Abstract: BackgroundDifferent ultrasound parameters have been frequently used to assess changes associated with training, aging, immobilization, and neuromuscular diseases. However, an exploratory reliability analysis of the echo intensity (EI) and muscle thickness (MT) of the forearm flexors is scarce, especially in women.ObjectiveThe purpose of the present study was to determine the intra-rater reliability of MT and EI assessed by ultrasound in young women.MethodUltrasonographic MT and EI were acquired in the forearm … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 31 publications
0
9
1
Order By: Relevance
“…medial gastrocnemius, quadriceps, hamstrings, and biceps brachii), with different populations (men or women, young or elderly, and healthy or unhealthy) and in different positions (sitting or standing). 4,716 However, the results are not consistent amongst them, with reported reliabilities changing considerably from one study to another, with ICC values ranging between 0.31 and 0.96. 4,716…”
Section: Introductionmentioning
confidence: 78%
See 1 more Smart Citation
“…medial gastrocnemius, quadriceps, hamstrings, and biceps brachii), with different populations (men or women, young or elderly, and healthy or unhealthy) and in different positions (sitting or standing). 4,716 However, the results are not consistent amongst them, with reported reliabilities changing considerably from one study to another, with ICC values ranging between 0.31 and 0.96. 4,716…”
Section: Introductionmentioning
confidence: 78%
“…The intra-rater reliability compares the data collected by the same rater in different moments. 4 The inter-rater reliability compares the data collected by different raters in the same day. 5 The inter-analyst reliability uses images regardless of who collected them, comparing the analysis done by different analyzers.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, the error of the measure (SEM) and coeficient of variation (CV) of the pretest MT measurements of each experimental session were used to verify the intersession reliability. The SEM and CV were calculated using the following equations: SEM = SD × √1−ICC, and CV = SEM × Mean − 1 [25]. The proximal and middle RF muscle swelling, torque, and work output from each set were analyzed by a twoway repeated measure analysis of variance (ANOVA) (exercise protocol × time).…”
Section: Statistical Analysesmentioning
confidence: 99%
“…The main technical limitation of US is related to the dependence on raters’ perception which could lead to measurement errors and misinterpretation [1824]. Tiny changes or displacements coming from the ultrasonic head placement, as well as different pressure or orientation of the transducer, may significantly influence image acquisition [24]. For example, a tendon image acquired slightly oblique to the longitudinal axis of the structure may appear thicker than the image taken on its true axis [19].…”
Section: Introductionmentioning
confidence: 99%