2021
DOI: 10.1159/000516474
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasonographic Assessment of Extravascular Lung Water in Hospitalized Patients Requiring Hemodialysis: A Prospective Observational Study

Abstract: <b><i>Introduction:</i></b> Sonographic technologies can estimate extravascular lung water (EVLW) in hemodialysis (HD) patients. This study investigated the suitability of a handheld scanner in contrast to a portable scanner for quantifying EVLW in hospitalized patients requiring HD. <b><i>Methods:</i></b> In this prospective study, 54 hospitalized HD patients were enrolled. Bedside lung ultrasound was performed within 30 min before and after dialysis using handh… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 26 publications
1
5
0
Order By: Relevance
“…The measured values of Area 4, Area 6 and Area 8 are highly consistent with the measured values of dialysis patients diagnosed with pulmonary congestion using Area 28 method [21,22]. Moreover, the consistency of the scores of the B-line between observers was relatively high, and there was no obvious difference in the B-line detection results of different types of ultrasound equipment [7]. LUST' s sub-study aimed at clinicians who can master the B-lines measurement method quickly and effectively after online video training, as well as at nurses who can successfully evaluate B-lines for the differential diagnosis of acute dyspnoea with high accuracy [23].…”
Section: Discussionsupporting
confidence: 77%
See 3 more Smart Citations
“…The measured values of Area 4, Area 6 and Area 8 are highly consistent with the measured values of dialysis patients diagnosed with pulmonary congestion using Area 28 method [21,22]. Moreover, the consistency of the scores of the B-line between observers was relatively high, and there was no obvious difference in the B-line detection results of different types of ultrasound equipment [7]. LUST' s sub-study aimed at clinicians who can master the B-lines measurement method quickly and effectively after online video training, as well as at nurses who can successfully evaluate B-lines for the differential diagnosis of acute dyspnoea with high accuracy [23].…”
Section: Discussionsupporting
confidence: 77%
“…Before dialysis, excessive extravascular lung water was correlated with the amount of fluid accumulated before treatment. The nine articles reported that hemodialysis can rapidly reduce the severity of pulmonary congestion, and the number of B-lines changed significantly after dialysis [3][4][5][6][7][8][9][10][11]. The results of eight articles after meta-analysis had statistical significance, which demonstrates that LUS can dynamically monitor the volume status of dialysis patients in real time, as an attempt to more effectively assess the effect of dialysis [4][5][6][7][8][9][10][11].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In our study, we pragmatically combined 8-point measurement with HHUSD to enhance the portability of using LUS. HHUSD has been tested for LUS measurement in HD patients (22,23). Miao et al compared the use of HHUSD with a portable US machine, with comparable and concordant measurements of B lines both before and after HD (r 2 = 0.84), though with a signi cant bias of 0.06 (actual B line = 1.2, p = 0.04).…”
Section: -Point Lus In Hhusdmentioning
confidence: 99%