Ultrasonic Vitrectomy Performance Assessment Using Micro-Extensional Rheology

Abstract: Purpose The purpose of this study was to assess the performance of ultrasonic (US) vitrectomy devices by quantifying and comparing its impact on extracted vitreous properties to conventional pneumatic blade (PB) cutters using micro-extensional rheology. US vitrectomy is a new technology that offers an alternative to PB cutters used in vitreo-retinal surgeries. Methods Thirty-six porcine vitreous samples were extracted using US and PB cutters. Each sample was kept at 4°C… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0
1

Year Published

2023
2023
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 26 publications
0
3
0
1
Order By: Relevance
“…Finally, the indentation load was kept positive, suggesting that the force applied by the mechanical testing machine was higher than the surface tension. Therefore, the surface tension of the vitreous body could not be ignored, which was approved by previous studies [ 8 , 11 , 23 , 37 , 38 ]. The adhesive force of the vitreous body was measured by stretching the vitreous body between the cleated parallel plate and stage of the rheometer [ 8 ].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Finally, the indentation load was kept positive, suggesting that the force applied by the mechanical testing machine was higher than the surface tension. Therefore, the surface tension of the vitreous body could not be ignored, which was approved by previous studies [ 8 , 11 , 23 , 37 , 38 ]. The adhesive force of the vitreous body was measured by stretching the vitreous body between the cleated parallel plate and stage of the rheometer [ 8 ].…”
Section: Discussionmentioning
confidence: 99%
“…The adhesive force of the vitreous body was measured by stretching the vitreous body between the cleated parallel plate and stage of the rheometer [ 8 ]. Due to surface tension, an elasto-capillary liquid bridge formed between the probe and the vitreous body droplet as the sample dripped from the probe to the rest of the droplet [ 37 ]. The pressure acting on the indenter below zero during relaxation was probably affected by surface tension of the vitreous body [ 11 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Görev döngüsü, probun boşta veya aspire ederek (kapalı) geçirdiği süreye kıyasla keserek (açık) geçirdiği sürenin oranını temsil eder. 25,26 Görev döngüsü, vitrektomi ameliyatının verimliliğini ve etkinliğini etkileyen kritik bir parametredir. Kesme ve aspirasyon arasındaki dengeyi belirleyerek doku çıkarma oranını, uygulanan emme miktarını ve genel cerrahi sonuçları etkiler.…”
Section: Görev Döngüleriunclassified
“…To analyze the extensional rheological properties of the CSF, we adapted a simple rheometric method to apply a large strain rate to the samples (Figure 1) [21]. A droplet, typically between 50 and 100 μL, was dispensed onto a hydrophobically treated substrate to create a domed droplet.…”
Section: Micro-extensional Rheologymentioning
confidence: 99%