2019
DOI: 10.1136/bmjopen-2018-027725
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasonic strain elastography for detecting abnormalities in the supraspinatus tendon: an intra- and inter-rater reliability study

Abstract: ObjectivesThe reliability of ultrasonic strain elastography (SEL) used to detect abnormalities in the supraspinatus tendon is unclear. Thus, the aim of this study was to investigate the reliability of SEL in the supraspinatus tendon.DesignAn intra-rater and inter-rater reliability study.SettingA single-centre study conducted at the University of Southern Denmark.ParticipantsTwenty participants with shoulder pain and MRI-verified supraspinatus tendinosis and 20 asymptomatic participants (no MRI).Primary and sec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

1
30
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(31 citation statements)
references
References 49 publications
(59 reference statements)
1
30
0
Order By: Relevance
“…The supraspinatus tendons were scanned bilaterally while the patient was sitting in a custom-made chair ensuring the upper limb was held in a standardized position (at both baseline and follow-up), with the hand placed on the backrest, as previously described. 4 …”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The supraspinatus tendons were scanned bilaterally while the patient was sitting in a custom-made chair ensuring the upper limb was held in a standardized position (at both baseline and follow-up), with the hand placed on the backrest, as previously described. 4 …”
Section: Methodsmentioning
confidence: 99%
“…Where no such tendon changes were identified using conventional US, SEL was captured in a standardized position, with the probe placed laterally from the anterior-lateral corner of the acromion as previously described. 4 Image window depth and width and the tissue compression force technique were performed according to previous recommendations. 8 , 12 Only high-quality images, determined by an in-built software quality bar, were used for analysis, as recommended by the manufacturer (GE Healthcare, personal communication with application specialist in Ultrasound, Heidi Sørensen, 2018).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Acceptable intra-rater and inter-rater reliability were found using either of the SEL methods. However, the RAW variable had the highest reliability, and the measurement error from GEL exceeded the difference between healthy participants and patients [7].…”
mentioning
confidence: 93%