2017
DOI: 10.1109/jphot.2017.2702719
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasonic Sensitivity-Improved Fabry–Perot Interferometer Using Acoustic Focusing and Its Application for Noncontact Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
16
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 35 publications
(16 citation statements)
references
References 31 publications
0
16
0
Order By: Relevance
“…From Equation 9, it can be seen that η will equal ν when I 1 equals I 2 . Consequently, the degradation coefficient η can be measured through Equation (8). To make I 1 equal to I 2 , three steps should be followed: (1) Remove the FRM and record the results of the PDs.…”
Section: Performance Of Depolarization Fading With Self-designed Probementioning
confidence: 99%
See 2 more Smart Citations
“…From Equation 9, it can be seen that η will equal ν when I 1 equals I 2 . Consequently, the degradation coefficient η can be measured through Equation (8). To make I 1 equal to I 2 , three steps should be followed: (1) Remove the FRM and record the results of the PDs.…”
Section: Performance Of Depolarization Fading With Self-designed Probementioning
confidence: 99%
“…After the above three steps were implemented, three outputs of the PDs were acquired to measure the degradation coefficient η of three interference signals. The maximum and minimum of the interference intensity were acquired every 6 ms and the visibility was calculated according to Equation (8). First, the measured results were obtained under the condition with a Faraday rotator.…”
Section: Performance Of Depolarization Fading With Self-designed Probementioning
confidence: 99%
See 1 more Smart Citation
“…The sensitivity of the FPI is determined by the structure and material of the interferometer cavity [ 27 ]. Their low reflectance and multilayer structure result in a low signal-to-noise ratio (SNR) and the manufacturing process is complex [ 28 ]. It can only achieve point-based measurement.…”
Section: Introductionmentioning
confidence: 99%
“…Fiber-optic ultrasonic sensors have many advantages [ 2 , 3 , 4 ] compared with traditional electrical ultrasonic transducers, including a capacity to detect broad-band acoustic wave signals with high sensitivity and resist disturbance; good reusability; and improvement of the reliability and efficiency of ultrasonic detection. All these advantages are beneficial to improve the reliability and efficiency of imaging of seismic physical models (SPMs) [ 5 ]. The SPM is used to simulate the real geological structure in laboratories, which can set up a bridge between theories and field-scale experiments.…”
Section: Introductionmentioning
confidence: 99%