1995
DOI: 10.1007/bf00133175
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasonic findings in intraocular retinoblastoma and correlation with histopathologic diagnosis

Abstract: A and B-scan ultrasonographic records of 132 eyes of 126 patients with suspected retinoblastoma were evaluated retrospectively. Six patients had bilateral lesions. The results were compared with the histopathologic diagnoses obtained after enucleation in 129 cases and with the indirect ophthalmoscopic examination in 3 bilateral cases. Ultrasonographic diagnosis was correct in 115 cases (87.12%), false-negative in 12 cases (9.09%) and false-positive in 5 cases (3.79%). Echographic tumor typing was made in 88 ca… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0
1

Year Published

1998
1998
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(10 citation statements)
references
References 13 publications
0
9
0
1
Order By: Relevance
“…These tumors usually demonstrate high internal reflectivity although the amount of reflectivity depends on the amount of calcification. Calcification can be seen in about 50-80% of cases of retinoblastoma [14,15] but if present confirms the diagnosis. Ultrasound in this case helped in the diagnosis of the condition of the child even before subjecting them to examination under anesthesia.…”
Section: Applications Of Ultrasound B-scan In Pediatric Glaucomas Rul...mentioning
confidence: 90%
“…These tumors usually demonstrate high internal reflectivity although the amount of reflectivity depends on the amount of calcification. Calcification can be seen in about 50-80% of cases of retinoblastoma [14,15] but if present confirms the diagnosis. Ultrasound in this case helped in the diagnosis of the condition of the child even before subjecting them to examination under anesthesia.…”
Section: Applications Of Ultrasound B-scan In Pediatric Glaucomas Rul...mentioning
confidence: 90%
“…Several reports showed a high accuracy of ultrasonographic diagnosis. [3][4][5] However, only one report in the litera- 718 FETAL RETINOBLASTOMA J Ultrasound Med 17:717-720, 1998…”
Section: Discussionmentioning
confidence: 99%
“…Ultrasonography has been used to reveal calcifications within the tumour and to evaluate extrascleral and optic nerve invasion. [1][2][3][4][5][6] After treatment, ultrasonography and ophthalmoscopy are the main tools used to evaluate intraocular tumour regression. [7][8][9][10] Computer assisted three dimensional ultrasonography (3DUS) has become available to ophthalmological oncology.…”
mentioning
confidence: 99%