Ultrasonic assessment of optic nerve sheath to detect increased intracranial pressure

Abstract: Purpose: Increased intracranial pressure (ICP) is one of the prevalent symptoms of trauma, especially traumatic headache, which requires quick action for the diagnosis and treatment. The optic nerve sheath diameter (ONSD) is a newly proposed technique for the detection of an increase in ICP. The aim of this study was to assess the efficacy of this new diagnostic method in patients with increased ICP induced by trauma. Methods: This prospective study was conducted betwee… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 31 publications
0
5
0
Order By: Relevance
“…Intracranial pressure increase (RICP) was defined either as a pressure of > 20 mmHg over a period of time [ 45 , 47 , 52 , 53 , 55 ] or clear signs of intracranial pressure on CT [ 46 , 48 51 , 54 , 56 59 ].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Intracranial pressure increase (RICP) was defined either as a pressure of > 20 mmHg over a period of time [ 45 , 47 , 52 , 53 , 55 ] or clear signs of intracranial pressure on CT [ 46 , 48 51 , 54 , 56 59 ].…”
Section: Resultsmentioning
confidence: 99%
“…Further cut-off values for an increased ICP can be found in appendix (p.13) [ 46 51 , 53 , 54 , 57 59 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“… Chen 2019 [ 14 ] China Prospective 29 4.53 DelicaMVU-6300 Mixed LP Mixed 3 mm behind the globe; averaged two measurements: one sagittal and the other in the transverse plane del Saz-Saucedo 2016 [ 15 ] Spain Prospective 19 6.76 Toshiba AplioXG Mixed LP IIH Transverse plane Du 2020 [ 16 ] China Prospective 49 5.7 Sonosite ICU Inv Trauma 3 mm behind the globe; transverse plane; averaged two eyes. Geeraerts 2007 [ 17 ] France Prospective 15 6.3 HP Sonos 5500 ICU Inv Trauma 3 mm behind the globe; one sagittal and one transverse Goel 2008 [ 18 ] India Prospective 73 5.8 Unspecified Mixed CT Trauma 3 mm behind the globe; one sagittal and one transverse; averaged Hanafi 2019 [ 19 ] Iran Prospective 62 …”
Section: Resultsmentioning
confidence: 99%