2019
DOI: 10.1002/mrm.27812
|View full text |Cite
|
Sign up to set email alerts
|

Ultrashort echo time magnetic resonance fingerprinting (UTE‐MRF) for simultaneous quantification of long and ultrashort T2 tissues

Abstract: Purpose To demonstrate an ultrashort echo time magnetic resonance fingerprinting (UTE‐MRF) method that allows quantifying relaxation times for muscle and bone in the musculoskeletal system and generating bone enhanced images that mimic CT scans. Methods A fast imaging steady‐state free precession MRF sequence with half pulse excitation and half projection readout was designed to sample fast T2 decay signals. Varying echo time (TE) of a sinusoidal pattern was applied to enhance sensitivity for tissues with shor… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

4
20
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 11 publications
(24 citation statements)
references
References 62 publications
4
20
0
Order By: Relevance
“…Note also that the same holds by increasing the milk concentration. This result ties well with previous studies wherein T 2 was mostly defined by the gelling agent concentration, whereas T 1 was mainly varied by incorporating different concentrations of paramagnetic ion salts 22–24 …”
Section: Discussionsupporting
confidence: 91%
See 1 more Smart Citation
“…Note also that the same holds by increasing the milk concentration. This result ties well with previous studies wherein T 2 was mostly defined by the gelling agent concentration, whereas T 1 was mainly varied by incorporating different concentrations of paramagnetic ion salts 22–24 …”
Section: Discussionsupporting
confidence: 91%
“…Their tissue-like MR signal makes them the material of choice for MRI studies. [21][22][23][24][25][26][27] In fact, a wide variety of agarbased phantoms simulating specific body parts, such as prostate, 27 carotid, 21 and brain, 26 have been proposed in the literature for evaluating new MR protocols and imaging techniques. This phantom type has also been quite widely used for thermal studies with FUS, 3,[28][29][30][31] where agar served as the gelling agent, and proper concentration of other materials was added to modify mainly the thermal and acoustical properties depending on the tissue to be mimicked.…”
Section: Introductionmentioning
confidence: 99%
“…Due to extremely low T2 values of the bone, MRF will match its evolution curve with the dictionary curve that has a very large T1 value, that is, low signal intensity. Potential solutions include the integration of machine‐learning for MRF pattern recognition and the combination with the ultrashort TE technique with MRF . Finally, all in vivo measurements were performed without contrast in this study.…”
Section: Discussionmentioning
confidence: 99%
“…Potential solutions include the integration of machine-learning for MRF pattern recognition and the combination with the ultrashort TE technique with MRF. 52 Finally, all in vivo measurements were performed without contrast in this study. However, postcontrast images are often needed to help delineate lesions.…”
Section: Discussionmentioning
confidence: 99%
“…For MRI‐only simulation, MRF provides absolute quantifications of tissue properties that naturally help improve tissue characterization. MRF has more consistent contrasts 6 among different tissues that reduce the uncertainty of synthetic CT. Ultra‐short echo time MRF 89 was also recently developed to improve the quantification and differentiation of bony structure and air cavity for synthetic CT. Machine learning based synthetic CT generation approaches have demonstrated excellent efficiency and reasonable accuracy in tissue classification 90 . So far majority of studies in this category focused on conventional T 1 ‐/T 2 ‐weighted images, where potential unwanted bias can be introduced through sophisticated processing steps such as intensity normalization.…”
Section: Introductionmentioning
confidence: 99%