2017
DOI: 10.1016/j.bios.2016.08.049
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasensitive, label-free detection of cardiac biomarkers with optical SIS sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
16
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 29 publications
(17 citation statements)
references
References 51 publications
1
16
0
Order By: Relevance
“…The excited states of dye molecules make a near-field coupling with bimetallic film for surface plasmons at λem. The non-radiative coupling of the excited molecules into surface plasmons at the dielectric-metal interface, a sort of non-radia decay of a dye molecule, occurs only for those spaced close to the metal film, i.e., th Surface plasmon resonance 0-0.160 µg mL −1 0.068 ng mL −1 [22] Optical solution immersed silicon 0.005-10 ng mL −1 5 and 10 pg mL −1 [45] It is worth noting that the SPCE technologies not only enhance the fluorescent signals detected but also suppress photobleaching due to the near field coupling of excited state dye molecules with thin metal layers that support surface plasmon resonance. To comprehend the superior performance of the SPCE chip over the control chip, let us begin by considering that the LED light source excites the molecules of the dye, the Alexa 488, which are conjugated with the detection antibody (D-Ab@Alexa 488) for the sandwich immune reaction.…”
Section: Resultsmentioning
confidence: 99%
“…The excited states of dye molecules make a near-field coupling with bimetallic film for surface plasmons at λem. The non-radiative coupling of the excited molecules into surface plasmons at the dielectric-metal interface, a sort of non-radia decay of a dye molecule, occurs only for those spaced close to the metal film, i.e., th Surface plasmon resonance 0-0.160 µg mL −1 0.068 ng mL −1 [22] Optical solution immersed silicon 0.005-10 ng mL −1 5 and 10 pg mL −1 [45] It is worth noting that the SPCE technologies not only enhance the fluorescent signals detected but also suppress photobleaching due to the near field coupling of excited state dye molecules with thin metal layers that support surface plasmon resonance. To comprehend the superior performance of the SPCE chip over the control chip, let us begin by considering that the LED light source excites the molecules of the dye, the Alexa 488, which are conjugated with the detection antibody (D-Ab@Alexa 488) for the sandwich immune reaction.…”
Section: Resultsmentioning
confidence: 99%
“…In another study, non-linear optical Stokes ellipsometry was used for imaging the non-linear susceptibility tensor of collagen [227]. Ellipsometric sensors have also been fabricated in conjunction with solution immersed silica immunosensors for the rapid (5 min) determination of cTnI in blood serum [228].…”
Section: Ellipsometric Biosensorsmentioning
confidence: 99%
“…Diware et al developed a solution-immersed silicon biosensor for myocardial infarction early diagnosis. Due to this sensor having a very high sensitivity on the thickness of the biolayer under the nonreflection condition, it would become a candidate for detecting biomarkers or other biological information from humans [ 180 ].…”
Section: Other Biomarker Sensorsmentioning