2022
DOI: 10.1007/s11548-022-02695-z
|View full text |Cite
|
Sign up to set email alerts
|

UltrARsound: in situ visualization of live ultrasound images using HoloLens 2

Abstract: Purpose Augmented Reality (AR) has the potential to simplify ultrasound (US) examinations which usually require a skilled and experienced sonographer to mentally align narrow 2D cross-sectional US images in the 3D anatomy of the patient. This work describes and evaluates a novel approach to track retroreflective spheres attached to the US probe using an inside-out technique with the AR glasses HoloLens 2. Finally, live US images are displayed in situ on the imaged anatomy. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 31 publications
1
7
0
Order By: Relevance
“…Second, we paid closer attention to the latency between the reslicing of the CT volume in 3D Slicer and its display in the glasses ( image reception ). This second analysis, which aligns with [ 14 ], allowed us to compare our system with the existing research in the field. This experiment was repeated 30 times for each time range.…”
Section: Methodsmentioning
confidence: 84%
See 2 more Smart Citations
“…Second, we paid closer attention to the latency between the reslicing of the CT volume in 3D Slicer and its display in the glasses ( image reception ). This second analysis, which aligns with [ 14 ], allowed us to compare our system with the existing research in the field. This experiment was repeated 30 times for each time range.…”
Section: Methodsmentioning
confidence: 84%
“…To ensure effective communication across platforms, it is crucial that the exchange of information is seamless and allows for real-time perception. In line with the approach taken by [ 14 ], we measured latency by counting the number of frames it took from a change in one of the platforms to be reflected in the other one in a slow-motion video. The video was captured at a rate of 120 Hz through the glasses, where both the holographic information and the 3D Slicer screen containing the analogous models were always visible.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…All of these factors were likely an unwanted distraction throughout the task. Investigating other probe tracking approaches, e.g., using retroreflective spheres, as described in [ 11 ], would be an important step to further develop this system.…”
Section: Discussionmentioning
confidence: 99%
“…To minimize technical complexity, we preferred an inside-out tracking approach compatible with the HRM by using the built-in QR code tracking [ 10 ]. As the HRM does not provide access to the sensor data, we could not utilize a previously published tracking approach using retroreflective spheres [ 11 ]. For US data acquisition, we used an EPIQ 7 station (Philips Medical Systems International B.V., Best, The Netherlands) that allows real-time streaming of image data to the computer via a proprietary network protocol provided by Philips.…”
Section: Methodsmentioning
confidence: 99%