2017
DOI: 10.1021/acs.analchem.7b01553
|View full text |Cite
|
Sign up to set email alerts
|

Ultrafast Screening and Quantitation of Pesticides in Food and Environmental Matrices by Solid-Phase Microextraction–Transmission Mode (SPME-TM) and Direct Analysis in Real Time (DART)

Abstract: The direct interface of microextraction technologies to mass spectrometry (MS) has unquestionably revolutionized the speed and efficacy at which complex matrices are analyzed. Solid Phase Micro Extraction-Transmission Mode (SPME-TM) is a technology conceived as an effective synergy between sample preparation and ambient ionization. Succinctly, the device consists of a mesh coated with polymeric particles that extracts analytes of interest present in a given sample matrix. This coated mesh acts as a transmissio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
88
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 112 publications
(88 citation statements)
references
References 81 publications
0
88
0
Order By: Relevance
“…In comparison with other AIMS methods, DART has the benefit of not requiring the addition of solvent post‐extraction in order to desorb samples, thus eliminating the need for extraneous input. SPME‐TM DART has already demonstrated its ability to handle time efficiently, but analyses had yet to be carried out on a one‐by‐one basis . In addition, the use of a 96‐SPME format is not a novel concept.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…In comparison with other AIMS methods, DART has the benefit of not requiring the addition of solvent post‐extraction in order to desorb samples, thus eliminating the need for extraneous input. SPME‐TM DART has already demonstrated its ability to handle time efficiently, but analyses had yet to be carried out on a one‐by‐one basis . In addition, the use of a 96‐SPME format is not a novel concept.…”
Section: Resultsmentioning
confidence: 99%
“…Thus far, SPME‐TM publications have focused on using rapid agitation of each mesh on a vortex (i.e. 3000 rpm) . This approach has worked well due to the high surface area of the mesh, which allows for adequate pre‐concentration in a short period of time.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The headspace solid‐phase microextraction (HS‐SPME) sampling followed by GC coupled with MS analysis (HS‐SPME‐GC/MS) can be used as a method for investigating emission profiles. Historically, the use of SPME in chemical analysis was confined to HS sampling, but currently, SPME is used for different analytical tasks. By implementing the HS‐SPME technique, researchers can perform reliable analysis of VOCs of different kind of samples, such as foodstuffs, plants and their metabolites .…”
Section: Introductionmentioning
confidence: 99%